| 数据搜索系统,热门电子元器件搜索 |
|
MDM2A-24-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MDM2A-24-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 3 page ![]() MODEL: MDM2A-24 MDM2A-24 SPECIFICATIONS ES-8214 Rev.8 Page 1/3 https://www.m-system.co.jp/ Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR STANDARD SIGNAL LINE & PULSE USE (life monitor, 24 V DC line voltage) Functions & Features • Designed specifically for 4 – 20 mA DC and pulse signal line including both 4-wire and 2-wire transmitters • Absorbs surges only without affecting instrumentation signal • Life monitor function helps you to decide when you should replace the surge protector; reduces maintenance and prevents downtime • LED display and alarm contact output indicate the degradation and life span of the surge protection circuits 29.5 [1.16] 76 [2.99] 124 [4.88] Model ALM PWR mm [inch] MODEL: MDM2A–24–[1] ORDERING INFORMATION • Code number: MDM2A-24-[1] Specify a code from below for [1]. (e.g. MDM2A-24-M2) [1] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Housing material: Flame-resistant resin (black) Alarm indicators PWR: The green LED turns on while the power is supplied. ALM: Tricolor LED (green/amber/red) · Remains off when the power supply is first turned on. · Green: The unit has received one or more surges. · Amber: Replacement is recommended. · Red: The life span has ended. Degradation judged: When the leakage current at the voltage limiter exceed approx. 7.5 μA. Life time judged: When the number of discharges of the discharge element reaches the expected life span. Alarm output: The N.C. contact is on when the life span of the discharge elements has ended, when the voltage limiter has degraded, and/or when the power supply is removed. Rating: 125 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage: 125 V AC or 110 V DC Maximum switching power: 62.5 VA or 30 W Minimum load: 5 V DC @ 1 mA INSTALLATION Power consumption •AC: Approx. 2 VA at 100 V Approx. 3 VA at 200 V Approx. 4 VA at 240 V •DC: Approx. 1.5 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lb) PERFORMANCE Discharge voltage (peak voltage) Line to line: 30 V min. Line to ground: ±300 V min. Maximum surge voltage Line to line: 45 V max. Line to ground: ±650 V max. (The maximum voltage that could pass through M-RESTER. Protected equipment must be able to withstand this voltage for very short time period.) Response time: ≤ 0.1 μsec. Leakage current: Line to line: ≤ 5 μA @ 30 V DC Line to ground: ≤ 5 μA @ ±140 V DC Discharge current capacity: 5000 A (8 / 20 μsec.) Max. load current: 100 mA Insulation resistance: ≥ 100 MΩ with 500 V DC (surge protector circuit to alarm output to power) Dielectric strength: 2000 V AC @ 1 minute |
类似零件编号 - MDM2A-24-R |
|
类似说明 - MDM2A-24-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |