| 数据搜索系统,热门电子元器件搜索 |
|
MDM2AT-65-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MDM2AT-65-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 3 page ![]() MODEL: MDM2AT MDM2AT SPECIFICATIONS ES-8229 Rev.3 Page 1/3 https://www.m-system.co.jp/ Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR STANDARD SIGNAL LINE & PULSE USE (life monitor, 24 V, 48 V or 65 V DC line voltage, photovoltaic system, instrument shelter) Functions & Features • Designed specifically for 4 – 20 mA DC and pulse signal lines • Absorbs surges only without affecting instrumentation signal • Life monitor function helps you to decide when you should replace the surge protector; reduces time and effort for maintenance and prevents downtime • LED display and alarm output indicate the degradation and life span of the surge protection circuits • Wide range of operating temperature from -20 to +70°C (-4 to +158°F) 29.5 [1.16] 76 [2.99] 124 [4.88] Model ALM PWR mm [inch] MODEL: MDM2AT–[1]–[2] ORDERING INFORMATION • Code number: MDM2AT-[1]-[2] Specify a code from below for each of [1] and [2]. (e.g. MDM2AT-24-M2) [1] NOMINAL VOLTAGE 24: 24 V DC 65: 48 V or 65 V DC [2] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Housing material: Flame-resistant resin (black) Alarm indicators PWR: The green LED turns on while the power is supplied. ALM: Tricolor LED (green/amber/red) · Remains off when the power supply is first turned on. · Green: The unit has received one or more surges. · Amber: Replacement is recommended. · Red: The life span has ended. Degradation judged: When the leakage current at the voltage limiter exceed approx. 7.5 μA. Life time judged: When the number of discharges of the discharge element reaches the expected life span. Alarm output: The N.C. contact is on when the life span of the discharge elements has ended, when the voltage limiter has degraded, and/or when the power supply is removed. Rating: 125 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage: 125 V AC or 110 V DC Maximum switching power: 62.5 VA or 30 W Minimum load: 5 V DC @ 1 mA INSTALLATION Power consumption •AC: ≥ 2.3 VA at 100 V ≥ 3.5 VA at 200 V ≥ 4.6 VA at 240 V •DC: ≥ 1.7 W Operating temperature: -20 to +70°C (-4 to +158°F) Storage temperature: -30 to +70°C (-22 to +158°F) Operating humidity: 10 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lb) PERFORMANCE Max. continuous operating voltage (Uc): Line to line: 30 V (24 V DC use), 70 V (48 V or 65 V DC use) Line to earth: ±140 V Voltage protection level (Up): Line to line: 45 V max. (24 V DC use), 100 V max. (48 V or 65 V DC use) Line to earth: ±650 V max. Response time: ≤ 0.1 μsec. Leakage current: Line to line: ≤ 5 μA @ max. voltage |
类似零件编号 - MDM2AT-65-R |
|
类似说明 - MDM2AT-65-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |