| 数据搜索系统,热门电子元器件搜索 |
|
47DV-1111-R 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
47DV-1111-R 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 13 page ![]() MODEL: 47DV 47DV SPECIFICATIONS ES-9501 Rev.17 Page 3/13 https://www.m-system.co.jp/ Protected time duration: No limit INPUT SPECIFICATIONS 1 – 5V 0.6 – 5.4V 1M Ω minimum MEASURING RANGE TYPE ID OPERATIONAL RANGE INPUT IMPEDANCE ±5V -6 – +6V 1M Ω minimum ±200V -240 – +240V 1M Ω minimum ±20V -24 – +24V 1M Ω minimum INPUT CODE: 1 (DC voltage) 4 – 20mA 2.4 – 21.6mA 10Ω 0 – 20mA -2 – +22mA 10Ω ±200mA -240 – +240mA 1Ω ±20mA -24 – +24mA 10Ω MEASURING RANGE TYPE ID OPERATIONAL RANGE INPUT IMPEDANCE INPUT CODE: 2 (DC current) DC OUTPUT SIGNAL SPECIFICATIONS TYPE ID LOAD RESISTANCE OPERATIONAL RANGE OUTPUT RANGE 2000Ω minimum -0.5 – +5.5V 0 – 5V 4000Ω minimum -6 – +6V ±5V TYPE ID LOAD RESISTANCE OPERATIONAL RANGE OUTPUT RANGE 400Ω maximum -2 – +22mA 0 – 20mA 400Ω maximum 2.4 – 21.6mA 4 – 20mA 8000Ω minimum -12 – +12V ±10V VOLTAGE OUTPUT CURRENT OUTPUT I/O OPTIONS ■ Event Trigger Input: Dry contact or NPN open collector Input current: ≤ 3 mA Sensing: 6 V Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF Signal ID and Details S-TMR: Startup Timer Measuring starts in the predetermined time after detecting the signal turning on. TIMING: Timing Used for various timing hold functions ZERO: Forced Zero Forced Zero and tare adjustment are externally controlled when ZERO signal is turned on/off. HOLD: Hold data Reading measured signal stops and the last value is held when HOLD signal is turned on. RESET: Reset data The device is reset when RESET signal is turned on. ■ Alarm Output: Relay contact Rated load: 250 V AC @ 3 A (cos ø = 1) 30 V DC @ 3 A (resistive load) Maximum switching voltage: 250 V AC, 30 V DC Maximum switching power: 750 VA, 90 W (resistive load) Minimum load: 5 V DC @ 10 mA Mechanical life: ≥ 5 × 106 cycles (rate 180 cycles/min.) ■ Alarm Output: Photo MOSFET relay Rated load: 120 V AC/DC @ 80 mA (resistive load) ON resistance: 25 Ω Permissible loss: 250 mW ■ Network Interface Transmission: Half-duplex, asynchronous, no procedure Interface: Conforms to TIA/EIA-485-A Max. transmission distance: 500 meters Baud rate: 1.2 – 38.4 kbps Max. number of nodes: 31 (except the master) Protocol: Modbus RTU Parity: None, odd or even Stop bit: 1 bit, 2 bits Node address: 1 to 247 Media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) Terminating resistor: Built-in (Connect across T2 - T3, when the unit is the end of the line) ■ BCD Output + Control Signals • Input Signals: Dry contact or NPN open collector Input current: ≤ 3 mA Sensing: 6 V Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF Signal ID and Details REQ: Request BCD data Valid data in approx. 30 msec. after detecting the signal’s rising edge MIN_REQ: Request Minimum reading data Valid data in approx. 30 msec. after detecting the signal’s rising edge MAX_REQ: Request Maximum reading data Valid data in approx. 30 msec. after detecting the signal’s rising edge HOLD: Hold data Reading measured signal stops and the last value is held when HOLD signal is turned on. RESET: Reset data All BCD data turn off when RESET signal is turned on. • Output Signals: NPN open collector Max. load voltage: 24 V DC Max. load current: 10 mA Saturation voltage: ≤ 0.3 V Leakage current: ≤ 500 μA Signal ID and Details DATA (Do 11...Do 68): BCD Output data in 6 digits Do 1x = LSD ... Do 6x = 6th LSD |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |