| 数据搜索系统,热门电子元器件搜索 |
|
47LT-102G-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
47LT-102G-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 8 page ![]() MODEL: 47LT 47LT SPECIFICATIONS ES-9512 Rev.11 Page 2/8 https://www.m-system.co.jp/ • Input type • Alarm setpoint • Hysteresis (deadband) • Others (Refer to the instruction manual for details) Read rate: 40 times/sec. (25 msec.) Averaging: None or moving average Lockout setting: Prohibiting certain operations; protecting settings DISPLAY Display: 16 mm (.63) high, 4 digits, 7-segment LED Display range: -1999 to 9999 Minimum display/setting scale: 1°C or 1°F (0.1°C for K and J, narrow span) Decimal point position: 10–1 or none (fixed depending upon the input type) Zero indication: Higher-digit zeros are suppressed. Over-range indication: ‘S.ERR’ and ‘Min’ or ‘Max’ blinking when the input signal is out of the usable range. Burnout indication: ‘B.ERR’ blinking Alarm status indication LL indicator: Green turns on when the LL alarm is tripped. L indicator: Green turns on when the L alarm is tripped. H indicator: Red turns on when the H alarm is tripped. HH indicator: Red turns on when the HH alarm is tripped. P indicator: Amber turns on when none of the other alarms is tripped. Note: Only ‘P’ turns on with no-alarm-output type. ‘LL’ or ‘HH’ does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. Function indicators: Ini, Alm, D/P, Adj, Fnc, Min, Max Display mode status and operation status, amber ON or blink Engineering unit indication: Sticker label attached DC, AC, mV, V, kV, μA, mA, A, kA, mW, W, kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec, m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h, N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J, kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc. INPUT SPECIFICATIONS Input resistance: 1 MΩ minimum Burnout sensing: ≤ 0.1 μA Default input type: K (CA) Temperature Range THERMOCOUPLE CONFORMANCE USABLE RANGE RANGE (PR) °C 0 to 1700 -30 to +1730 °F 32 to 3092 -22 to +3146 K (CA) °C -200 to +1300 -230 to +1330 °F -328 to +2372 -382 to +2426 K (CA), narrow span °C -100.0 to +450.0 -199.9 to +500.0 E (CRC) °C 0 to 600 -30 to +630 °F 32 to 1112 -22 to +1166 J (IC) °C -100 to +850 -130 to +880 °F -148 to +1562 -202 to +1616 J (IC), narrow span °C -100.0 to +350.0 -150.0 to +400.0 T (CC) °C -200 to +400 -230 to +430 °F -328 to +752 -382 to +806 B (RH) °C 400 to 1800 70 to 1830 °F 752 to 3272 158 to 3326 R °C 200 to 1700 -30 to +1730 °F 392 to 3092 -22 to +3146 S °C 0 to 1700 -30 to +1730 °F 32 to 3092 -22 to +3146 N °C -200 to +1300 -230 to +1330 °F -328 to +2372 -382 to +2426 OUTPUT SPECIFICATIONS ■ DC Output • DC Current Operational range: -5 – +105 % • DC Voltage Operational range: -5 – +105 % ■ Alarm Output: Relay contact Rated load: 250 V AC @ 3 A (cos ø = 1) 30 V DC @ 3 A (resistive load) Maximum switching voltage: 250 V AC, 30 V DC Maximum switching power: 750 VA, 90 W (resistive load) Minimum load: 5 V DC @ 10 mA Mechanical life: ≥ 5 × 106 cycles (rate 180 cycles/min.) INSTALLATION Power consumption •AC: Approx. 6.5VA •DC: Approx. 3 W Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 300 g (0.66 lb) PERFORMANCE Accuracy Display: ±1°C (or ±1.8°F) ±1 digit (PR, K, E, J, T) ±2°C (or ±3.6°F) ±1 digit (B, R, S, N) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |