| 数据搜索系统,热门电子元器件搜索 |
|
48NDVA-2BCA-R 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
48NDVA-2BCA-R 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 9 page ![]() MODEL: 48NDVA 48NDVA SPECIFICATIONS ES-9441 Rev.13 Page 3/9 http://www.m-system.co.jp/ INPUT SPECIFICATIONS ■ DC Current: 0 – 50 mA DC; input resistor incorporated Minimum span: 1 mA When specifying a resistance value, choose from below. 5.1 Ω, 10 Ω, 12 Ω, 20 Ω, 39 Ω, 200 Ω ■ DC Voltage: -10 – +10 V DC Input resistance: ≥ 1 MΩ Minimum span: 0.1 V Offset: Max. 1.5 times span OUTPUT SPECIFICATIONS ■ DC Output • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 11 V max. • DC Voltage: -10 – +10 V DC Minimum span: 1 V Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V ■ Alarm Output: Relay contact Rated load: 250 V AC @1 A (cos ø = 1) 30 V DC @5 A (resistive load) Maximum switching voltage: 250 V AC, 220 V DC Maximum switching power: 380 VA, 150 W Minimum load: 5 V DC @100 mA Mechanical life: ≥ 5 × 108 cycles (rate 180 cycles/min.) 0 50 100 Input (%) L Setpoint H Setpoint H Output L Output • Alarm Output Code 2 Alarm Trip Operation Terminal No. in parentheses (7–8)ON (12–14)ON (13–14)ON (7–9)ON 0 50 100 Input (%) L H HH Output LL Output H Output L Output HH LL • Alarm Output Code 4 Terminals 7 – 9, 13 – 14 turn on at a loss of power. Terminals 7 – 9, 13 – 14 turn on at a loss of power. (7–8)ON (7–9)ON (7–10)ON (11–14)ON (12–14)ON (13–14)ON INSTALLATION Power Consumption •AC: Approx. 5.5 VA at 100 V with max. load Approx. 7 VA at 200 V with max. load Approx. 8 VA at 264 V with max. load •DC Approx. 3.5 W at 20.4 V with max. load Approx. 3.5 W at 24 V with max. load Approx. 3.5 W at 27.6 V with max. load Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 300 g (0.66 lb) PERFORMANCE in percentage of span Accuracy: ±1 % ±1 digit (bargraph) ±0.5 % ±1 digit (digital indicator) ±0.1 % DC output Temp. coefficient: ±0.015 % of FS/°C (±0.008 % of FS/°F) (Display) ±0.02 %/°C (±0.01 %/°F) (DC output) Response time: ≤ 0.5 sec. (Display: moving average sample number set to 4) ≤ 1.0 sec. (DC output : 0 – 90 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 min. (input to DC output to alarm output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (alarm output) Installation Category II (power) Pollution degree 2 Input to alarm output to power: Reinforced insulation (300 V) DC output to power: Reinforced insulation (300 V) RoHS Directive EN 50581 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |