| 数据搜索系统,热门电子元器件搜索 |
|
48NDR-2G0-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
48NDR-2G0-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 10 page ![]() MODEL: 48NDR 48NDR SPECIFICATIONS ES-9443 Rev.13 Page 2/10 http://www.m-system.co.jp/ SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9436) BEZEL OPTION Bezels are used to adapt the 48N Series to an existing panel cutout. In order to replace M-System’s 48 Series products, use the one attached to the 48N Series as standard. When the existing panel is cut according to DIN standard, specify ‘/D’ suffix code. For a new installation, no bezel is required. Please refer to ‘Mounting Requirement’ and mount the 48N directly. Ingress protection is invalid when the 48N is mounted with a bezel, or when multiple modules are stacked side by side. SPARE PARTS • Scale plate GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP65; applicable to the front panel for single unit mounted according to the specified panel cutout Connection: M3 separable screw terminal (torque 0.6 N·m) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Zero adjustment: 0 – 10 % (front) Span adjustment: 90 to 100 % (front) Scale plate: Flame resistant resin (white scale & characters on black base) H & L alarm output delay: 0 sec. (factory setting; fieldselectable between 0 and 15 sec. by 1 sec. increments) Setpoint adjustment 2 points: H [L setpoint ] to 100 % L 0 to [H setpoint] or No alarm trip 4 points: HH [H setpoint] to 100 % H [L setpoint] to [HH setpoint] L [LL setpoint] to [H setpoint] LL 0 to [L setpoint] or No alarm trip Alarm deadband (hysteresis): 1 % Burnout: Upscale standard; downscale optional. The 100 % position bargraph segment and 115 % value of the digital meter blink with upscale burnout; the 0 % position bargraph segment and -15 % value of the digital meter blink with downscale burnout. Linearization: Standard Setting: (Front button) • Zero and span adjustments • Alarm setpoint • Others (Refer to the instruction manual for details) Read rate: 10/s Moving average sample number: 4 (factory setting; field selectable among 1, 2, 4, 8 or 16) LED brightness adjustment: 7 levels ■ BARGRAPH LED: 101-segment LED, 100 mm (3.96”) long, 3.00 mm (.12”) wide Display range: 0 to 100 (scaling function not available) (0 % or 100 % position bar blinks when over range) Scale: Two different scales available for single bargraph Characters: Max. 4 characters including decimal point and negative sign Divisions: Min. 22, max. 100 Engineering unit: Max. 6 characters ■ DIGITAL DISPLAYS LED: 7-segment red LED, character 8 mm (.31”) high Number of digits: 4 digits Setting range: -1999 to 9999 (Min. 3 significant digits) Minimum scale value: 100 (3 digits, the decimal point position disregarded) Scaled range: The range between -1999 to 9999 and -15 to +115 % of input span (The indicator blinks when the input is out of the range) Decimal point position: 10–1, 10–2, 10–3 or none Zero indication: Higher-digit zeros are suppressed Engineering unit: Max. 6 characters on scale plate INPUT SPECIFICATIONS Maximum leadwire resistance: 200 Ω per wire (3-wire) Sensing current: ≤ 1 mA |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |