2 / 5 page ![]() MODEL: R30YS4 R30YS4 SPECIFICATIONS ES-9006 Rev.4 Page 2/5 https://www.m-system.co.jp/ PERFORMANCE Conversion accuracy: ±0.1 % Conversion rate: 10 msec. Data range: 0 – 10000 of the output range Data allocation: 4 Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Output delay time: ≤ 250 msec. (0 - 90 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (output 1 to output 2 to output 3 to output 4 to internal bus or internal power) 1500 V AC @ 1 minute (power input to FE; isolated by the power supply module) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive FUNCTIONS ■ Output at the loss of communication • Output Hold If the network module is in error, the module holds the signal at error and stands by until the communication recovers. • Output set value If the network module is in error, the module holds the signal at error or power up and stands by until the communication recovers. The the signal at error or power up is selectable with PC configurator software (Model: R30 CFG) Not depending on output at the loss of communication setting, when power up the module holds the signal at error or power up and stands by until the normal data is received. ■ OUTPUT WIRE BREAKDOWN DETECTION In the case of wire breakdown, output error is detected. Then, the ERR indicator LED blinks in red and the flag of error is set on the PLC etc. PC CONFIGURATOR The following parameters can be set with using PC Configurator Software (model: R30CFG) Refer to the users manual for the R30CFG for detailed operation of the software program. ■ CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT SETTING Unused setting CH enabled CH disabled CH enabled Fine zero adjustment -320.00 – +320.00 (%) 0.00 (%) Fine gain adjustment -3.2000 – +3.2000 1.0000 Scaled range zero -32 000 – +32 000 0 Scaled range span -32 000 – +32 000 10 000 Output range at communication failure or power up -15.00 – +115.00 (%) -15.00 (%) ■ CHANNEL BATCH SETTING PARAMETER SETTING RANGE DEFAULT SETTING Simulate output Normal output Simulation data Normal output Output at the loss of communication Hold the output data User set data output Hold the output data |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |