| 数据搜索系统,热门电子元器件搜索 |
|
R1MS-GH3T-R 数据表(PDF) 4 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R1MS-GH3T-R 数据表(HTML) 4 Page - M-System Co.,Ltd. |
|
4 / 8 page ![]() MODEL: R1MS-GH3 R1MS-GH3 SPECIFICATIONS ES-5671 Rev.12 Page 4/8 http://www.m-system.co.jp/ COMMUNICATION CABLE CONNECTIONS R1M T1 T2 T3 T4 R1M T1 T2 T3 T4 T1 T2 T3 T4 R1M RS-232-C RS-485 *1 *1 *1. Internal terminating resistor is used when the device is at the end of a transmission line. *2. Install shielded cables to all sections and ground them at single point. *2 FG RS-485 CONNECTION DIAGRAM RS-232-C T3 T4 T2 T1 T7 T6 T5 Term. Resist. Control Circuit *1. When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal T2 – T3 with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin. *2. Separate sets of terminals for DC and TC are assigned to each channel, however, DO NOT connect to both sets of terminals at once. Duplicate connection may affect measuring accuracies. DC and TC can be mixed among eight channels. Note 1: Be careful to eliminate noise as much as possible by e.g. using shielded cables. Note 2: Be sure to earth the FG terminal and the cable shielding to a most stable earth point in the environment. Note 3: Resistor modules (model: REM3-250) can be used to convert current inputs into voltage. However, use of REM3 is not recommended when TC inputs are mixed because the heat developed on and around the REM3 affects the cold junction compensation performance. + – + – ext. wire ext. wire ext. wire ext. wire ext. wire ext. wire ext. wire ext. wire Power Circuit + – Shielded Twisted-pair Cable To Other I/O Modules Jumper * 1 FG U (+) V (–) POWER JACK CONFIGURATOR Isolated Analog Input 1 Isolated Analog Input 2 Isolated Analog Input 3 Isolated Analog Input 4 Isolated Analog Input 5 Isolated Analog Input 6 Isolated Analog Input 7 Isolated Analog Input 8 Isolated Alarm Output Isolated Trigger Input *2 + – T/C INPUT 1 DC 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 + – + – + – T/C INPUT 2 DC + – + – + – T/C INPUT 3 DC + – + – + – T/C INPUT 4 DC + – + – + – T/C INPUT 5 DC + – + – + – T/C INPUT 6 DC + – + – + – T/C INPUT 7 DC + – + – + – + – T/C INPUT 8 DC ALARM OUTPUT TRIGGER INPUT Caution: FG terminal is NOT a protective conductor terminal. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |