6 / 12 page ![]() MODEL: R3-NMW1F R3-NMW1F SPECIFICATIONS ES-8286 Rev.1 Page 6/12 http://www.m-system.co.jp/ MODBUS I/O ASSIGNMENT ADDRESS DATA FORMAT NAME Coil (0X) 1 – 1024 Digital Output (discrete output) 1025 Main / Sub Switching Command (valid only with SW3-3 set to ON) Inputs (1X) 1 – 1024 Digital Input (discrete input) 1025 – 1040 Module Status 1041 – 1056 Error Status 1057 – 1072 Data Error Status Input Registers (3X) 1 – 256 I Analog Input 257 – 768 F Analog Input Holding Registers (4X) 1 – 256 I Analog Output 257 – 768 F Analog Output I : Integer, 0 – 10000 (0 – 100%) F : Floating (32-bit data cannot be accessed using oating addresses.) Note: DO NOT access addresses other than mentioned above. Such access may cause problems such as inadequate operation. • Module Status indicates whether individual I/O modules are mounted or not. The bit corresponding to the mounted slot turns to “1”, and the unmounted slot to “0”. • Error Status indicates error status for each module as described below. The bit corresponding to such module turns to “1”. R3-TSx, R3-RSx, R3-US4: Input burnout R3-DA16A: Power input in error or disconnected R3-YSx: Output current error (e.g. load unconnected) R3-PC16A: External power supply in error or disconnected • Data Error Status indicates overrange (R3-US4: out of -10% to +110%; the other types: out of -15% to +115%) status for each module. The bit corresponding to such module turns to “1”. • Main / Sub Switching Commands given to the network modules result as follows: MAIN’ MODULE ‘SUB’ MODULE OUTPUT MODE 1 0 Main bus is used; Red LED turns on at RUN LED of the I/O modules. 0 1 Sub bus is used; Green LED turns on at RUN LED of the I/O modules. 1 1 Main bus is used; Amber LED turns on at RUN LED of the I/O modules. 0 0 Output is invalid; RUN LED of the I/O modules turns off. • Writing to Coil (0X) and Holding Registers (4X) is only available with either Wireless or Modbus communication. It is available to change the con guration with Con gurator Software (model: R3CON). Factory default setting is Modbus communication. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |