| 数据搜索系统,热门电子元器件搜索 |
|
R3-NM4-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-NM4-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 8 page ![]() MODEL: R3-NM4 R3-NM4 SPECIFICATIONS ES-8331 Rev.6 Page 1/8 http://www.m-system.co.jp/ Remote I/O R3 Series MODBUS INTERFACE MODULE (for 115.2 kbps) 109 (4.29) 27.5 (1.08) 130 (5.12) mm (inch) MODEL: R3-NM4-[1][2] ORDERING INFORMATION • Code number: R3-NM4-[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3-NM4-M2/Q) • Specify the specification for option code /Q (e.g. /C01/SET) [1] POWER INPUT N: No power supply AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz)* DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) * * Not selectable for use with independent power modules or network modules with the internal power input options. [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-8331) PACKAGE INCLUDES... • Terminating resistor (110 Ω, 0.25 W) GENERAL SPECIFICATIONS Connection Modbus: Euro type connector terminal (applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm) Internal bus: Via the Installation Base (model: R3-BSx) Internal power: Via the Installation Base (model: R3-BSx) Power input, RUN contact output: M3 separable screw terminal (torque 0.5 N·m) Screw terminal: Nickel-plated steel Isolation: Modbus to internal bus or internal power to power input to RUN contact output to FG Input error data: Input value setting at input module error with side DIP SW Main/Sub switching control in dual communication mode: Selectable with the side DIP SW (refer to the manual) Dual communication setting: Set with the side DIP switch Data allocation setting: Set with the side DIP switch RUN indicator: Bi-color (green/red) LED; Green ON in normal communication; Red ON when receiving data (Function selected with DIP SW) ERR indicator: Bi-color (green/red) LED; green ON at data receiving error (blinking with configuration error); Red ON at EEPROM error; Red blinks when transmitting data (Function selected with DIP SW) ■ RUN CONTACT OUTPUT RUN contact: Turns ON while the green RUN LED is ON (Modbus in normal communication). Rated load: 250 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 0.5 A (resistive load) Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 250 VA or 150 W Minimum load: 1 V DC @ 1 mA Mechanical life: 2 × 107 cycles (300 cycles/min.) When driving an inductive load, external contact protection and noise quenching recommended. |
类似零件编号 - R3-NM4-R |
|
类似说明 - R3-NM4-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |