4 / 7 page ![]() MODEL: R3-NM3 R3-NM3 SPECIFICATIONS ES-8330 Rev.7 Page 4/7 http://www.m-system.co.jp/ MODBUS I/O ASSIGNMENT ADDRESS DATA FORMAT NAME Coil (0X) 1 – 1024 Digital Output (discrete output) 1025 Main / Sub Switching Command (valid only with SW3-3 set to ON) Inputs (1X) 1 – 1024 Digital Input (discrete input) 1025 – 1040 1041 – 1056 1057 – 1072 Input Registers (3X) 1 – 256 I Analog Input 257 – 768 F Analog Input Holding Registers (4X) 1 – 256 I Analog Output 257 – 768 F Analog Output 2001 – 50000 Error Status Data Error Status Module Status Extension I/O I: Integer, 0 – 10000 (0 – 100%) F: Floating (32-bit data cannot be accessed using floating addresses.) Note: DO NOT access addresses other than mentioned above. Such access may cause problems such as inadequate operation. • Module Status indicates whether individual I/O modules are mounted or not. The bit corresponding to the mounted slot turns to “1,” and the unmounted slot to “0.” • Error Status indicates error status for each module as described below. The bit corresponding to such module turns to “1.” R3-TSx, R3-RSx, R3-US4: Input burnout R3-DA16A: Power input in error or disconnected R3-YSx: Output current error (e.g. load unconnected) R3-PC16A: External power supply in error or disconnected • Data Error Status indicates overrange (R3-US4: out of -10% to +110%; the other types: out of -15% to +115%) status for each module. The bit corresponding to such module turns to “1.” • Main / Sub Switching Commands given to the network modules result as follows: • For Extension I/O, the mapping of 3000 words per each I/O module is available as shown in the table below. The mapping contents depends on each module characteristics; refer to each instruction manual. SLOT ADDRESS 1 200 1 – 5000 2 500 1 – 8000 3 800 1 – 11000 4 1100 1 – 14000 14 4400 1 – 47000 15 4700 1 – 50000 : : ‘MAIN’ MODULE ‘SUB’ MODULE OUTPUT MODE 1 0 0 1 1 1 0 0 Main bus is used; Red light turns on at RUN LED of the I/O modules. Sub bus is used; Green light turns on at RUN LED of the I/O modules. Main bus is used; Amber light turns on at RUN LED of the I/O modules. Output is invalid; RUN LED of the I/O modules turns off. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |