| 数据搜索系统,热门电子元器件搜索 |
|
R3-NEIP1/CE 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-NEIP1/CE 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 6 page ![]() MODEL: R3-NEIP1 R3-NEIP1 SPECIFICATIONS ES-8466 Rev.6 Page 3/6 https://www.m-system.co.jp/ TRANSMISSION DATA DESCRIPTIONS ■ OUTPUT DATA The figure below shows the allocation of the data sent from the network module to the master. ■ INPUT DATA The figure below shows the allocation of the data sent from the master to the network module. The DIP SW located at the side of the module specifies each I/O module's data allocation (occupied data area and size of the I/O data area). For example, when the data areas are assigned as shown below: Module 1 4 Module 2 4 Module 3 4 Module 4 1 Module 5 1 Module 6 1 Module 7 1 I/O data area: 252 words each for input and output. Then the I/O data are assigned as in the figures below: 0 15 +0 +2 +4 +6 +8 +10 +12 +14 Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Module Status Error Status Data Error Status Begin Address 0 15 +0 +2 +4 +6 +8 +10 +12 +14 Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Begin Address The area enclosed with bold line is assigned for I/O data Module Status, Error Status and Data Error Status are assigned to the last three words of the output data respectively. Each module can handle either input or output data. • Module Status indicates whether individual I/O module are mounted or not. The bit corresponding to the mounted slots turns to “1,” and the unmounted slots to “0.” • Error Status indicates error status for each module as described below. The bit corresponding to such modules turns to “1.” R3-TSx, R3-RSx, R3-US4 (T/C or RTD input): Input burnout R3-DA16A: Power input in error or disconnected R3-YSx: Output current error (e.g. load unconnected) R3-PC16A: External power supply in error or disconnected • Data Error Status indicates overrange (R3-US4: out of -10% to +110%; the other types: out of -15% to +115%) status for each module. The bit corresponding to such modules turns to “1.” +249 +251 +249 +251 : : : : +16 +16 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |