| 数据搜索系统,热门电子元器件搜索 |
|
R3-NE1-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-NE1-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 8 page ![]() MODEL: R3-NE1 R3-NE1 SPECIFICATIONS ES-8361 Rev.24 Page 1/8 https://www.m-system.co.jp/ Remote I/O R3 Series ETHERNET INTERFACE MODULE (Modbus/TCP) 109 [4.29] 27.5 [1.08] 130 [5.12] mm [inch] MODEL: R3-NE1-[1][2] ORDERING INFORMATION • Code number: R3-NE1-[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3-NE1-R/CE/Q) • Specify the specification for option code /Q (e.g. /C01/SET) [1] POWER INPUT N: No power supply (Use with Ver.2.00 or higher versions of Power Supply Module (model: R3-PSx) to conform with CE marking.) AC Power K3: 100 – 120 V AC (Operational voltage range 85 - 132 V, 47 - 66 Hz) * (CE not available) L3: 200 – 240 V AC (Operational voltage range 170 - 264 V, 47 - 66 Hz) * (CE not available) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) * * Not selectable for use with independent power modules or network modules with the internal power input options. [2] OPTIONS (multiple selections) Standards & Approvals blank: Without CE /CE: CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-8361) RELATED PRODUCTS • PC configurator software (model: R3CON) Downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Connection Ethernet: RJ-45 connector Internal bus: Via the Installation Base (model: R3-BSx) Internal power: Via the Installation Base (model: R3-BSx) Power input, RUN contact output: M3 separable screw terminal (torque 0.5 N·m) Screw terminal: Nickel-plated steel Isolation: Ethernet to internal bus or internal power to power supply to RUN contact output to FG Input error data setting: Input value setting at input module error with side DIP SW Dual communication setting: Set with the side DIP switch Data allocation setting: Set with the side DIP switch RUN indicator: Bi-color (green/red) LED; Green ON in normal communication; Red ON when receiving data (Function selected with DIP SW) ERR indicator: Bi-color (green/red) LED; Green ON or blinking at communication error; Red ON at transmitting data (Function selected with DIP SW) ■ RUN CONTACT OUTPUT RUN contact: Turns ON while the green RUN LED is ON (Ethernet in normal communication). Rated load: 250 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 0.5 A (resistive load) (Less than 50 V AC to conform with EU Directive) Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 250 VA or 150 W Minimum load: 1 V DC @ 1 mA Mechanical life: 2 × 107 cycles (300 cycles/min.) When driving an inductive load, external contact protection and noise quenching recommended. |
类似零件编号 - R3-NE1-R |
|
类似说明 - R3-NE1-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |