1 / 7 page ![]() MODEL: R3-RR8 R3-RR8 SPECIFICATIONS ES-8432 Rev.10 Page 1/7 https://www.m-system.co.jp/ Remote I/O R3 Series REMOTE CONTROL RELAY CONTROL MODULE (Do 8 points) Functions & Features • Controls remote control relays for lighting control with Fieldbus • Applicable to the remote control relays already installed • Monitors status of remote control relays with feedback inputs from signal lines Typical Applications • Monitors and controls of lighting in buildings 109 [4.29] 27.5 [1.08] 130 [5.12] mm [inch] MODEL: R3-RR8[1][2] ORDERING INFORMATION • Code number: R3-RR8[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3-RR8W/CE/Q) • Specify the specification for option code /Q (e.g. /C01) NO. OF CHANNELS 8: 8 [1] COMMUNICATION MODE S: Single W: Dual [2] OPTIONS (multiple selections) Standards & Approvals blank: Without CE /CE: CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating RELATED PRODUCTS • Interface Module (model: R3-NC1, NC3, NE1, NM1, NM3, NM4, NDx, NF2, NFL1) Firmware version V2.00 or higher. R3-NF2 is available with firmware version V0.04 or higher., RECOMMENDED PRODUCTS (OPERATION CHECKED) Remote control relay: BR-12D, BR-22D (Mitsubishi Electric) WR6165 (Panasonic) Remote control transformer: BRT-10B, BRT-20B (Mitsubishi Electric) WR2301 (Panasonic) GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Output: M3 separable screw terminal (torque 0.5 N·m) Internal power: Via the Installation Base (model: R3-BSx) Screw terminal: Nickel-plated steel Isolation: Output to internal bus or internal power Input Data Length: 8 bit, 16 bit selectable with DIP switch Output data length: 8 bit, 16 bit selectable with DIP switch RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Green LED; OFF in abnormality; ON in normal operating conditions. Input output status indicator: Red LED; 1 to 8: Output bit status, turns on with bit set ON. 9 to 16: Feedback input status, turns on with the input ON. OUTPUT SPECIFICATIONS Number of output: 8 points Common: All 8 points (12 terminal) Rated load voltage: 24 V AC ±10 % (supplied by the remote control transformer) Load voltage frequency: 50 / 60 Hz Maximum outputs provided at once: No limit Output ON duration: 100 msec. |
类似零件编号 - R3-RR8S/Q |
|
类似说明 - R3-RR8S/Q |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |