2 / 7 page ![]() MODEL: R7G4HML3-6-YSF4 R7G4HML3-6-YSF4 SPECIFICATIONS ES-7772-G Rev.0 Page 2/7 http://www.m-system.co.jp/ MECHATROLINK-III COMMUNICATION Baud rate: 100 Mbps Transmission distance: 6300 m max. Distance between stations: 100 m max. Transmission media: MECHATROLINK cable (Model JEPMC- W6013-x-E, Yaskawa Controls Co., Ltd.) Connector: TYCO AMP Industrial mini I/O connector Max. number of slaves: 62 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit) Transmission cycle: 125 µsec., 250 µsec., 500 µsec., 1 – 64 msec. (with 1 msec. increments) Communication cycle: 125 µsec. through 64 msec. Applicable profile: Standard I/O profile (cyclic communication) Event-driven communication acquiring ID profile (event- driven communication) Transmission bytes: 16 bytes Station address: 03H through EFH (set with rotary switches) Cyclic communication: Available Event-driven communication: Available Slave monitoring: None OUTPUT SPECIFICATIONS Output range: 4 to 20 mA DC Load resistance: ≤ 550 Ω Operational range: -15 to +115 % of output range INSTALLATION Current consumption •DC: Approx. 150 mA Operating temperature: -10 to +55°C (14 to 131°F) Storage temperature: -20 to +65°C (-4 to +149°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface or DIN rail (35 mm rail) Weight: 220 g (0.49 lb) PERFORMANCE Conversion accuracy: ±0.1 % Conversion rate: 200 μsec. per 4 channels Data range: 0 – 10000 of the output range Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Output delay time: ≤ 250 μsec. (0 - 90 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Isolation: 1500 V AC @ 1 minute (output 0 to output 1 to output 2 to output 3 MECHATROLINK or FE to power) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581 PC CONFIGURATOR The following parameters can be set with using PC Configurator Software (model: R7CFG) Refer to the users manual for the R7CFG for detailed operation of the software program. ■ SETTINGS FOR INDIVIDUAL CHANNELS PARAMETER SETTING RANGE DEFAULT SETTING Validating/ Invalidating Valid Invalid Valid Bias adjustment -320.00 - +320.00 (%) 0.00 (%) Gain adjustment -3.2000 - +3.2000 1.0000 Zero scale -32000 - +32000 0 Full scale -32000 - +32000 10000 Output reset value -15.00 - +115.00 (%) -15.00 (%) ■ SETTINGS FOR ALL CHANNELS PARAMETER SETTING RANGE DEFAULT SETTING Setting indication for output function at the loss of communication Hold the output Output reset value Hold the output |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |