51 / 55 page ![]() MODEL: R7HL R7HL SPECIFICATIONS ES-7812 Rev.18 Page 51/55 http://www.m-system.co.jp/ DC VOLTAGE OUTPUT MODULE, 2 points MODEL: R7HL-YV2 SPECIFICATIONS Isolation: Output 0 to output 1 to power input to HLS to FG Data allocation: 2 Converted data range: 0 – 10000 of the output range Output range Wide span voltage: -10 – +10 V DC, -5 – +5 V DC, 0 – 10 V DC, 0 – 5 V DC, 1 – 5 V DC Narrow span voltage: -1 – +1 V DC, 0 – 1 V DC, -0.5 – +0.5 V DC Operational range: -15 – +115 % of the output range (except -10 – +10 V DC); approx. -11.5 – +11.5 V DC (-10 – +10 V DC) Load resistance: ≥ 100 kΩ Conversion accuracy: ±0.1 % Response time: 250 msec. (0 – 90 %) Temperature coefficient: ±0.015 %/°C (±0.008 %/°F) OPERATING MODE SETTING (*) Factory setting Caution ! - SW1-1 and SW1-2 are unused. Be sure to turn off unused ones. • Output Range (SW1-3, 1-4, 1-5, 1-6) SW1-3 SW1-4 SW1-5 SW1-6 Output range OFF OFF OFF OFF -10 – +10V DC (*) ON OFF OFF OFF -5 – +5V DC OFF ON OFF OFF -1 – +1V DC ON ON OFF OFF 0 – 10V DC OFF OFF ON OFF 0 – 5V DC ON OFF ON OFF 1 – 5V DC OFF ON ON OFF 0 – 1V DC ON ON ON OFF -0.5 – +0.5V DC ON ON ON ON PC Con gurator setting • Output at the Loss of Communication (SW1-7) SW1-7 Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (to -15% or approx. -11.5 V DC) • Transfer Rate (SW1-8) SW1-8 Transfer rate OFF 12Mbps (*) ON 6Mpbs TERMINAL ASSIGNMENTS 6 NC 7 VH0 8 VL0 1 NC 2 COM0 3 COM0 9 VH1 4 COM1 10 VL1 5 COM1 NO. ID FUNCTION NO. ID FUNCTION 1 NC No connection 6 NC No connection 2 COM0 Common 0 7 VH0 Wide span volt. 0 3 COM0 Common 0 8 VL0 Narrow span volt. 0 4 COM1 Common 1 9 VH1 Wide span volt. 1 5 COM1 Common 1 10 VL1 Narrow span volt. 1 CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. Control Circuit 3 7 8 2 1 5 9 10 4 VH0 VL0 COM0 COM0 VH1 VL1 COM1 COM1 6 4 5 2 1 3 FG 6 7 24V DC 0V TXD– (NC) TXD+ (NC) RXD– (TR–) RXD+ (TR+) Comm. Circuit ■ Output Connection Examples OUTPUT 0 VHn VLn + – COMn WIDE SPAN VOLTAGE VHn VLn + – COMn NARROW SPAN VOLTAGE Isolation Output Circuit Output Circuit OUTPUT 1 Note: Terminal numbers in parentheses are for half-duplex communication model. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |