| 数据搜索系统,热门电子元器件搜索 |
|
R7I4DECT-1-PA8A-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R7I4DECT-1-PA8A-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 7 page ![]() MODEL: R7I4DECT-1-PA8A R7I4DECT-1-PA8A SPECIFICATIONS ES-7779-F Rev.0 Page 2/7 http://www.m-system.co.jp/ 2.5 mA Input current: ≤ 11.2 mA per point at 24 V DC Input resistance: Approx. 2 kΩ Maximum input frequency: 10 kHz Pulse input minimum pulse width: ≥ 20 μsec. for both ON and OFF Reset input minimum pulse width: ≥ 1 msec. for both ON and OFF Accumulated pulse count: 0 - 4 294 967 295 Maximum accumulated pulse count: 1 - 4 294 967 295 Overflow reset value: 0 or 1 Count reset: Host PC/PLC or external reset Preset pulse count: Can be set to a desired value from the host device or on PC configurator software. INSTALLATION Current consumption: Approx. 50 mA (rated current 8 A) Operating temperature: -10 to +55°C (14 to 131°F) Storage temperature: -20 to +65°C (-4 to +149°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface or DIN rail (35 mm rail) Weight: 170 g (0.37 lb) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input or sensor excitation to EtherCAT or FE to power) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581 PC CONFIGURATOR The following parameters can be set with using PC Configurator Software (model: R7CFG) Refer to the users manual for the R7CFG for detailed operation of the software program. ■ CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT Unused channels Invalid (checked), Valid (unchecked) Valid Maximum accumulated pulse count 1 to 4294967295 4294967295 Over ow reset value 0 or 1 0 Preset pulse count 0 to max. accumu- lated pulse count 0 ■ CHANNEL BATCH SETTING PARAMETER SETTING RANGE DEFAULT Edge direction for counting pulses Falling edge (DI-ON) or Rising edge (DI-OFF) Falling edge (DI-ON) Edge direction for resetting pulse count by reset terminal Falling edge (DI-ON) or Rising edge (DI-OFF) Falling edge (DI-ON) Pulse count reset by reset terminal Enable or Disable Disable Pulse count reset / preset by master Enable or Disable Disable |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |