| 数据搜索系统,热门电子元器件搜索 |
|
OMT550-R200-2EP-IO 数据表(PDF) 3 Page - Pepperl+Fuchs Inc. |
|
|
|||||||||||||||||||||||||||||
OMT550-R200-2EP-IO 数据表(HTML) 3 Page - Pepperl+Fuchs Inc. |
|
3 / 4 page ![]() Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com Distance sensor OMT550-R200-2EP-IO 3 Table 1: Information on Measured Value Filters Teach-In (TI) Use the rotary switch for switching signal Q1 or Q2 to select the relevant switching threshold A and/or B to teach in. • The yellow LEDs indicate the current state of the selected output. To teach in a switching threshold, press and hold the "TI" button for approximately 1 s, until the yellow and green LEDs flash in phase. Teach-in starts when the "TI" button is released. • Teach-in successful: the yellow and green LEDs flash alternately at 2.5 Hz. • Teach-in unsuccessful: the yellow and green LEDs quickly flash alternately at 8 Hz. After an unsuccessful Teach-in, the sensor continues to operate with the previous valid setting after the relevant visual fault signal is issued. Set switching mode: you can define different switching modes by teaching in the relevant distance data for switching thresholds A and B. 1. Single point mode: 2. Window mode: Teach in switching thresholds: you can teach in or overwrite a taught-in switching threshold at any time. To do this, press the "TI" button again. Reset a value: you can reset a taught-in value. To do this, press the "TI" button for > 4 s, until the yellow and green LEDs go out. The reset process itself starts when the "TI" button is released. • Reset successful: the yellow and green LEDs flash alternately at 2.5 Hz. Resetting to Factory Settings To revert back to factory settings, press the "TI" button for > 10 s with the rotary switch set to position "O," until the yellow and green LEDs go out at the same time. The reset process itself starts when the "TI" button is released. • Reset to factory settings successful: the yellow and green LEDs light up at the same time. The sensor then continues to operate with factory settings. OMT • Factory setting for switching signal Q1: Switching signal is high active, window mode • Factory setting for switching signal Q2: Switching signal is high active, window mode Setting different operating modes via the IO-Link interface The devices are equipped with an IO-Link interface as standard for diagnostics and parameterization tasks to ensure optimum adjustment of the sensors to the relevant application. Single point mode operating mode (one switch point): • "Detection of objects irrespective of type and color in a defined detection range. Objects in the background are suppressed. • "The switch point corresponds exactly to the set point. Cable length 2 m Approvals and certificates UL approval E87056 , cULus Listed , class 2 power supply , type rating 1 CCC approval CCC approval / marking not required for products rated ≤36 V Measured value filter Filter 1-way 2-way 4-way 16-way 64-way 256-way Response time (ms) 2 4 8 32 128 512 Repeatability (%) < 1 % Settings B A leer A B leer BA A > B AB B > A Configuration via IO-Link interface |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |