| 数据搜索系统,热门电子元器件搜索 |
|
SC210W 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
SC210W 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 13 page ![]() MODEL: SC210W SC210W SPECIFICATIONS ES-6347 Rev.0 Page 2/13 http://www.m-system.co.jp/ • Loop Configuration Builder Software (model: SFEW3E) for function parameter setting, list printing and data downloading/uploading • PC Configurator Software (model: SCCFG) for exporting short trend data (CSV), and storing/transferring display parameter setting • Control and supervision by SCADA software via Modbus TCP/IP or RTU communication • Backup module (applicable to Mv2 only) is incorporated for manual loading: MV output is automatically switched to manual control in case of control module abnormality • Independently powered and controlled backup module • Easy extraction of control module at the front for replacement while MV output is maintained • Housing with selectable depth enabling use of existing wires at replacement: 300 mm and 400 mm • Separable terminal block • Expansion of operations blocks due to Expansion module Typical Applications • Replacement of conventional controllers • Panel operation for small-scale instrumentation RELATED PRODUCTS • PC Configurator cable (model: COP-US) • Loop configuration builder software (model: SFEW3E Ver. 1.101 or later) • PC configurator software (model: SCCFG Ver.1.84 or later) Builder software and configurator software are downloadable at M-System’s web site. ACCESSORIES • Precision resistor module (model: REM4): 2 units • Cold junction compensation sensor: 2 pcs • Mounting brackets: 2 pcs • Connector adapter: 1 pce (The jack on the unit and the plug of PC Configurator cable (not included in the product) are different in size.) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP55; ensured for the front panel of the unit independently mounted to a panel Connection Terminal screws: M3.5 screw terminals (torque 1.0 N·m) Terminal fixing screws: M4 screw terminals (torque 1.2 N·m) Backup module power supply terminal (option /M2, /R): Euro terminal block (wire dia. 2.4 max., 0.5 – 2.5 mm2, stripped length 10 mm) Ethernet: RJ-45 Modular Jack Screw terminal Terminal screws: Nickel-plated steel (standard) or stainless steel Terminal fixing screws: Chrome-plated steel Housing material: Flame-resistant resin (gray), steel Isolation: Pv1 to Pv2 to supply output to Ai1 or Ai2 or Ai3 or Ai4 to Di1 or Di2 or Di3 or Di4 or Di5 or Pi1 or Pi2 or Pi3 or Pi4 or Pi5 to Di6 or Pi6 to Mv1 to Mv2 or Mv2B to Ao1 or Ao2 to Do1 to Do2 to Do3 to Do4 to Do5 to Do6 to NestBus to Modbus-RTU to Modbus/TCP to power to backup module power to FG PID control: Single loop, cascade, advanced Proportional band (P): 1 to 1000 % Integral time (I): 0.01 to 100 minutes Derivative time (D): 0.01 to 10 minutes Auto-tuning: Limit cycle method Alarm: PV high & low, deviation, rate of change Computation: 48 functions blocks available for arithmetic operations, time functions, signal selection, limit, alarm and other functions Sequence operation: Logic sequence and step sequence (max. 1068 commands) Computation cycle: 100 msec. to 3 sec. (control cycle selectable among 1, 2, 4, 8, 16, 32 and 64 times of the computation cycle) MV output range: -15 - +115 % Parameter setting: With touch panel or PC (Loop Configuration Builder Software model: SFEW3E) Self diagnostics: CPU monitoring with a watchdog timer RUN contact: OFF in error detected by diagnostic (including NestBus) Short trend Storing interval: 1, 2, 5, 10, 20, 30 sec., 1, 2, 5, 10, 30, 60 min. Capacity: 400 points (display 200 points) ■ Display Display device: 4.3-inch TFT LCD Display colors: 256 Resolution: 480 × 272 pixels Pixel pitch: 0.198 × 0.198 mm (128 × 128 DPI) Backlight: LED Backlight life: Approx. 50 000 hours (at 50 % brightness) Note: The backlight can be replaced in M-System factory. The LCD must be replaced at the same time. Screen saver standby time: 1 to 99 minutes Scaling range: -32000 to +32000 Decimal point position: 10-1, 10-2, 10-3, 10-4, 10-5 or none Scale divisions: 2 to 10 Engineering unit indication: Max. 8 characters Auto/Man indicator: Green/Amber LED Backup mode MV output setting indicator: Blue LED |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |