| 数据搜索系统,热门电子元器件搜索 |
|
TM-R-H 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
TM-R-H 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 4 page ![]() ES-5221 Rev.9 MODEL Telemetering System TMR/TMT Functions & Features • Transmitting 1-point contact signal through NTT (Nippon Telephone & Telegraph) personal telecom- munication line of 50 b/s • Approved of Technical Requirements Compliance Approval by Japan Ap- proval Institute for Telecommunications Equipment • Approval No. M90-N227-0 • Applicable to vari- ous cables types • No interference by induction noise • Lightning protection applicable • No field adjust- ment required • Compact plug-in construction easy to install and maintain MODEL & SUFFIX CODE SELECTION TM❑–❑ MODEL INPUT Dry contact OUTPUT R : Relay contact T : Open collector POWER INPUT AC Power DC Power B : 100V AC G : 200V AC S : 12V DC* C :110V AC H : 220V AC R : 24V DC* D :115V AC J : 240V AC F : 120V AC *24V DC (Code R) and 12V DC (Code S) are not ap- proved by Japan Approvals Institute for Telecommu- nications Equipment. Therefore an individual application will be necessary for using the TMA on NTT telecom. line. CONTACT TELEMETERING MODULE P. 1 / 4 50 (1.97) 123 (4.84) 80 (3.15) mm (inch) TMR M•UNIT Model OFF ON OUTPUT ORDERING INFORMATION Specify code number. (e.g. TMR-B) GENERAL SPECIFICATIONS Construction: plug-in Connection: M3.5 screw terminals Housing material: flame-resistant resin (black) Isolation: input to output to power INPUT & OUTPUT ■INPUT: dry contact Sensing: approx. 18V DC @5mA ON/OFF level: ≤3kΩ for ON; ≥30kΩ for OFF Maximum leadwire resistance: 3kΩ including return ■OUTPUT •Relay Contact: 100V AC @5A (cosø=1) 24V DC @5A (resistive load) electrical life 10 × 104 cycles (rate 30/min.) Maximum switching voltage: 380V AC or 125V DC Maximum switching power: 500VA or 120W Minimum load: 5V DC @10mA (18V DC @5mA) Mechanical life: 5 × 107 cycles Maximum frequency: 1 Hz •Open Collector: 24V DC @100mA Maximum frequency: 20 Hz Saturation voltage: 1.8V DC Remark: The output pulse width is adjusted to 25 millisec. even when the input pulse width is narrower than 25 millisec. |
类似零件编号 - TM-R-H |
|
类似说明 - TM-R-H |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |