| 数据搜索系统,热门电子元器件搜索 |
|
USB2PMB1 数据表(PDF) 10 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
USB2PMB1 数据表(HTML) 10 Page - Maxim Integrated Products |
|
10 / 15 page ![]() Maxim Integrated │ 10 www.maximintegrated.com USB2PMB1# Adapter Board Evaluates: Munich (USB2PMB1#) a) Scope Options: On top right corner of the scope or the Histogram plot, plot settings options are avail- able for the user to play/pause, zoom in/out, pan, print, save, and waveform settings. b) Plot Configuration Options i) ADC Counts: This option plots the ADC code itself on the Y-axis with the number of samples on the X-axis. ii) Voltage: This option plots the converted volt- age value. iii) Current: Plots the current measured across the 250Ω shunt resistor present in Campbell. iv) 4-20mA to Temp: Plots the temperature mea- sured from IFM TA3231 temp sensor. This sensor sinks/ sources current proportional to the temperature measured. The shunt current and the temperature measured would also be indicated the bottom of the GUI. v) FFT: This option plots the FFT measurement on the Y-axis vs. frequency on the X-axis. vi) Histogram: This pushbutton option allows user to view the resultant output in Histogram. The X-axis is ADC code and the Y-axis is the number occurrence. vii) History Length: This option allows the user to view the history data by choosing the history length for viewing the data. c) Average: Drop-down box menu to choose to aver- age of the discrete values sampled. For instance, if 16 is selected, it takes the first 16 samples of the sample-shot the user takes, then averages them and shows the number in the text box below. If history is selected as well, it adds this number as a datapoint to the history. If all is selected, it uses all the samples taken, as selected in No of Samples to build the average. d) Calibrate: If the user wishes to calibrate, this option enables a real-time calibration for each channel and each signal input range; hence, providing a robust calibration/measurements at each single physical channel and each input signal range. See Figure 13. i) Shunt Resistor value: This option allows entering the exact value of shunt resistance in Cupertino board. This also allows the user to change the resistance and scale the current measured ii) Offset: The offset calibration is done by forc- ing the minimum voltage at input (based on the selection of input range) to obtain the plot counts. This plot counts value, if other than 0, should be fed in the offset digit tab. iii) Volt per LSB: This option calibrates for gain error. The volt per code calibration is done by forcing approximately 80% of specified voltage at the input to obtain the code. Here there are seven different input ranges. Use appropriate range selection for calibration. FullScale Input Range 16 Volt per LS V 21 B = − |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |