| 数据搜索系统,热门电子元器件搜索 |
|
WL40W1F-DS2-R 数据表(PDF) 5 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
WL40W1F-DS2-R 数据表(HTML) 5 Page - M-System Co.,Ltd. |
|
5 / 7 page ![]() MODEL: WL40W1F-DS2 WL40W1F SPECIFICATIONS ES-9084 Rev.0 Page 5/7 http://www.m-system.co.jp/ MODBUS FUNCTION CODES & SUPPORTED CODES Modbus function codes are shown below. ■ DATA AND CONTROL FUNCTION CODE NAME 01 Read Coil Status Digital output from the slave (read / write) 02 Read Input Status Status of digital inputs to the slave (read only) 03 Read Holding Registers General purpose register within the slave (read / write) 04 Read Input Registers Collected data from the eld by the slave (read only) 05 Force Single Coil Digital output from the slave (read / write) 06 Preset Single Registers General purpose register within the slave (read / write) 15 Force Multiple Coils Digital output from the slave (read / write) 16 Preset Multiple Registers General purpose register within the slave (read / write) ■ EXCEPTION CODE CODE NAME 01 Illegal Function Function code is not allowable for the slave 02 Illegal Data Address Address is not available within the slave 03 Illegal Data Value Data is not valid for the function 04 Slave Device Failure 05 Acknowledge 06 Slave Device Busy 07 Negative Acknowledge MODBUS I/O ASSIGNMENT ADDRESS DATA TYPE DATA Coil (0X) 1 – 16 Reserved (unused) Input (1X) 1 – 8 Reserved (unused) 9 Analog input error (input range error of analog input 1) 10 Analog input error (input range error of analog input 2) 11 – 16 Reserved (unused) Input Register (3X) 1 I Analog Input (analog input 1) 2 I Analog Input (analog input 2) 3 – 16 – Reserved (unused) Holding Register (4X) 1 – 16 – Reserved (unused) Note: DO NOT access addresses other than mentioned above. Such access may cause problems such as inadequate operation. ■ DATA TYPE I: Integer -32768 – +32767 ■ STATUS 1 bit: indicates input status. Input range error (Input range is out of the range -5 to +105% for scaling setting, or out of the range -32768 to +32767.) 0: Normal 1: Error INPUT DATA DESCRIPTIONS ■ANALOG DATA (16 BITS) 0 15 When the scaling setting is initial value, the data is 0 to 10000 for input 0 to 100% setting. If the input range is -5 to +105% (-500 to +10500) and that is out of range, the data is fixed to -500 or 10500. Minus value is converted into negative values, represented in 2’s complements. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |