2 / 2 page ![]() 2 www.protekdevices.com 05072.R2 1/03 CPE 80 & MB 80 INSTALLATION INSTRUCTIONS Maximum transient protection requires a good ground system. This consists of a common bonded or ground system, which interconnects AC power and data line grounds. A single ground connection is sufficient. However, it is more important that the ground be a low impedance path to the earth. A good earth connection is necessary for lightning transient threat conditions. Connections are usually best using a ground strap where the cross-sectional area of the ground connection is maximized. The ground connection is made through the green AC power ground wire or to a known earth ground system. If a ground wire is used, it is recommended that it is a #14 stranded wire. A low impedence ground is important to minimize a ground voltage potential rise that may cause ground bounce within the system or equipment. MB 80 INSTALLATION INSTRUCTIONS 1. Select a suitable mounting location within 10 meters of the protected equipment. An enclosure is recommended to protect against dust and moisture. 2. Mount the board using the stand-offs and #8 screws provided. 3. Connect wires to appropriate terminals as show in Figures 1 and 2. The ground wire MUST be kept on the unprotected side of the board. 4. Insert protected boards. Be certain to insert boards in the correct position as shown on the MB 80. CPE 80 INSTALLATION INSTRUCTIONS 1. Select a suitable mounting location within 10 meters of the protected equipment. 2. Remove the cover and install retainer assembly in holes. Do not tighten gland nut bushing. See cable retainer assembly detail in Figure 1. 3. Install base on a flat surface using #8 screws provided. 4. Insert wires through cable retainer assemblies and connect to appropriate terminals as shown in Figures 1 and 2. The ground wire MUST enter the enclosure ONLY through the unprotected side. 5. After completion of wiring, hand tighten gland nut bushing. 6. Insert protector boards. Be certain to insert boards in the correct position as shown on the printed circuit board. 7. Replace cover and tighten cover mounting screws. TYPICAL WIRING FORMAT FOR ONE 4 WIRE RS EIA STANDARD DATA LINE PRODUCTS Figure 1 Example of ProTek 15 pin protection board, such as 232B, 485B and TEL185B 2AP 4AP 3AP Peripheral Equipment Connect to CPU or PROTECTED SIDE 4FP 3FP 2FP 2GP 3GP 4GP 2HP 3HP 4HP 2CP 3CP 4CP 2DP 3DP 4DP 4EP 3EP 2EP Peripheral 2AP 3AP 4AP 4BP 3BP 2BP PROTECTED SIDE Connect to CPU or Equipment GROUND LUG Orient Board as Shown Orient Board as Shown Orient Board as Shown 1HP 4HU 3HU 2HU 1HU 4GU 3GU 2GU 2DU Orient Board as Shown Orient Board as Shown Orient Board as Shown 1GP 1EP 1FP 1GU 2FU 3FU 4FU 1EU 2EU 3EU 4EU 4DU 3DU 1FU Orient Board as Shown Orient Board as Shown 1DP 1BP 1CP 1DU 4CU 3CU 2CU 1BU 2BU 3BU 4BU 4AU 3AU 1CU Connect to External Data Lines UNPROTECTED SIDE 1AP R 2AU 1AU GROUND LUG Orient Board as Shown Data Lines External Connect to UNPROTECTED SIDE 1AP 1BP 1AU 2AU 1BU 3AU 4AU GROUND LUG To Common Equipment-Ground Point AWG 6-10 Wire Cover Bolt Mounting Screws 4 Wires per Data Line Inside Mouting Nut To Outside World Data Line Cable Gland Nut Retaining Nut Nylon Washer To Common Equipment-Ground Point AWG 6-10 Wire To Protected Equipment 4 Wires per Data Line CPE & MB 80 WIRING CONFIGURATION Figure 2 COPYRIGHT © ProTek Devices 2005 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products. ProTek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |