21 / 31 page ![]() ams Datasheet Page 21 [v2-06] 2014-Oct-14 Document Feedback AS5050A − Registers Possible Conditions which force the Error Flag to be set: • Wrong parity • Wrong command • Wrong number of clocks Note(s): If the error flag is set to 1 because of a communication problem the flag remains set until a Clear Error Flag Command is executed. No Operation (0x0000) The No Operation (NOP) command represents a dummy write to the AS5050A. If no error happens the chip responds with 0x0000. Figure 27: NOP Command AGC – Automatic Gain Control (0x3FF8) Writing a value different than zero to this register, stops the AGC loop and keeps a constant AGC value. Figure 28: AGC Angular Data (0x3FFF) Figure 29: Angular Data Bit 15 14 13 12 11 10 98765 4 3 2 1 0 Content 0 0 0 0 0 0 0 0 0 0 0 0 00 0PAR Name Read/Write Bit Position Description AGC R/W 5:0 Automatic Gain Control value Name Read/Write Bit Position Description Alarm Lo R 13 Alarm flag, which indicates a too weak magnetic field Alarm Hi R 12 Alarm flag, which indicates a too strong magnetic field Angle Value R 9:0 Angular value in 10 bit binary code |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|