  TL-Q5MC1-R Datasheet HTML 1Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 2Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 3Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 4Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 5Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 6Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 7Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 8Page - Omron Electronics LLC TL-Q5MC1-R Datasheet HTML 9Page - Omron Electronics LLC  
Zoom Inzoom in Zoom Outzoom out
 2 / 9 page
background image
TL-Q/TL-G
TL-Q/TL–G
2
Specifications
J RATINGS/CHARACTERISTICS
Part number
TL-Q2MC1
TL-Q5MD
j
TL-Q5MC
j
TL-G3D-3
Supply voltage
(operating voltage range)
12 to 24 VDC
(10 to 30 VDC),
ripple (p-p): 10% max.
12 to 24 VDC
(10 to 30 VDC)
12 to 24 VDC
(10 to 30 VDC),
ripple (p-p): 10% max.
12 to 24 VDC,
ripple (p-p): 5% max.
Current consumption
15 mA max. at 24 VDC
with no load
---
10 mA max. at 24 VDC
2 mA max. at 24 VDC
with no load
Leakage current
---
0.8 mA max.
---
---
Detectable object type
Ferrous metal (refer to
Engineering Data for non-ferrous metals)
Ferrous metal
Sensing distance
2 mm (0.079 in)
±15%
5 mm (0.19 in)
±10%
7.5 (0.29 in)
±0.5 mm
Sensing distance
(standard object)
0 to 1.5 mm (0.059 in)
(iron, 8 x 8 x 1 mm)
0 to 4 mm (0.157 in)
(iron, 18 x 18 x 1 mm)
0 to 4 mm (0.157 in)
(iron, 15 x 15 x 1 mm)
10 mm (0.394 in)
(iron, 10 x 5 x 0.5 mm)
Differential travel
10% max. of sensing distance
Control output
(switching capacity)
NPN open collector,
100 mA max. at 30 VDC
3 to 100 mA DC
NPN open collector,
50 mA max. at 30 VDC
NPN transistor output,
20 mA max.
Operating status
(with sensing object
approaching)
Load ON
D1 models: Load ON
D2 models: Load OFF
Refer to
Timing Charts.
C1 models: Load ON
C2 models: Load OFF
Load ON
Temperature influence
±10% max. of sensing
distance at 23
°C
(73.4
°F) in the
temperature range of
–10
°C to 60°C (14°F to
140
°F)
±10% max. of sensing
distance at 23
°C
(73.4
°F) in the
temperature range of
–25
°C to 70°C (-13°F to
158
°F)
±20% max. of sensing
distance at 23
°C
(73.4
°F) in the
temperature range of
–25
°C to 70°C (-13°F to
158
°F)
±10% max. of sensing
distance at 23
°C
(73.4
°F) in the
temperature range of
–10
°C to 55°C (14°F to
131
°F)
Voltage influence
±2.5% max. of sensing
distance within a range
of
±10% of the rated
power supply voltage
±2.5% max. of sensing
distance within a range
of
±15% of the rated
power supply voltage
±2.5% max. of sensing distance within a range of
±10% of the rated power supply voltage
Response time
---
2.0 ms max.
1 ms max.
Response frequency
(See Note.)
0.5 kHz
Circuit protection
Reverse connection
protection and surge
absorber
Load short-circuiting
protection and surge
absorber
Reverse connection
protection and surge
absorber
Surge absorber
Residual voltage
1.0 V max. with a load
current of 100 mA and
a cord length of 2 m
(78.74 in)
3.3 V max. with a load
current of 100 mA and
a cord length of 2 m
(78.74 in)
1.0 V max. with a load
current of 50 mA and
a cord length of 2 m
(78.74 in)
---
Indicator
Detection indicator
D1 models: Output
indicator (red) and
setting indicator (green)
D2 models: Output
indicator (red)
Detection indicator
---
Material
Case
Heat-resistant ABS resin
PPO
Sensing
surface
Heat-resistant ABS resin
PPO
Weight
Approx. 30 g (1.06 oz)
(with 2-m cable)
Approx. 45 g (1.59 oz)
(with 2-m cable)
Approx. 60 g (2.12 oz)
(with 2-m cable)
Approx. 30 g (1.06 oz)
(with 1-m cable)
Enclosure rating
IEC60529 IP67
IEC IP66
Ambient
temperature
Operating
–10
°C to 60°C (14°F to
140
°F) with no icing
–25
°C to 70°C (-13°F to 158°F) with no icing
Ambient
humidity
Operating
35% to 95%
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
(This table continues on the next page.)



Html Pages

1 2 3 4 5 6 7 8 9


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com