| 数据搜索系统,热门电子元器件搜索 |
|
ABGW110-R 数据表(PDF) 2 Page - IDEC Corporation |
|
|
|||||||||||||||||||||||||||||
ABGW110-R 数据表(HTML) 2 Page - IDEC Corporation |
|
2 / 41 page ![]() 697 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals File No. E68961 File No. LR21451 Certificate No. 2030010305027380 Registration No: J9551802 (E-Stops) Registration No: J9551803 (All other switches) Registration No: J9551804 (Pilot Lights) CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operating Temperature Operation: –25 to +50°C (without freezing), Storage: –40 to +80°C (without freezing) Vibration Resistance 5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6 Shock Resistance 1000m/sec2 (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 2 conforming to IEC60664-7 Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) IP65 from front of the panel; (IP54 for key switches) IP20 (Type HW-U contact block) Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches) Mechanical Life Momentary pushbuttons: 5,000,000 (1800 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 Rated Operational Characteristics AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or slow make NO, self-cleaning Recommended Terminal Torque Unit Wire Number of Wires Recommended Tightening Torque (Nm) Terminal Screw HW-U Contact Block Crimping Terminal 2 1.0 to 1.3 M3.5 Solid Wire ø0.5 to 1.6 mm (AWG14 to 22) 2 1.0 to 1.3 ø1.7 to 2.0 mm (AWG12) 1 1.2 to 1.3 Stranded Wire 0.3 to 2.0 mm2 (AWG14 to 22) 2 1.0 to 1.3 2.1 to 3.5 mm2 (AWG12) 1 1.2 to 1.3 Illuminated Unit (*1) Crimping Terminal 2 1.0 to 1.3 M3.5 Solid Wire ø0.5 to 1.6 mm (AWG14 to 22) Stranded Wire 0.3 to 2.0 mm (AWG14 to 22) Applicable Wire Size Pilot Light Crimping Terminal 2 0.6 to 1.0 (M3.0) 1.0 to 1.3 (M3.5) Solid Wire ø0.5 to 1.6 mm (AWG14 to 22) Stranded Wire ø0.3 to 2.0 mm (AWG14 to 22) 1. * refers to the lamp terminals of the illuminated push buttons and selector switches. External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50mΩ or less Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Lamp Ratings LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max Horsepower Rating 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor) Contact Material Silver Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Contact Block Type HW-U Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V Operational Current AC50/60Hz AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A DC DC-12 Control of resistive loads and solid state loads 10A 5A — 2.2A 1.1A — DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A — |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |