2 / 4 page ![]() Technical Data Power dissipation ≤ 500 mW , without modules Reverse polarity protection yes Redundancy Supply Redundancy available. The supply for the isolators is decoupled, monitored and fused. Fault indication output Connection X20: terminals 1(+), 2(-) Output type volt-free transistor output , not short-circuit protected , not overload protected Rated voltage Ur 30 V DC Rated current Ir 100 mA Signal level no fault: (external voltage) - 1 V max. for 100 mA (Tamb = 25 °C (77 °F)) power supply fault/module fault: blocked output (off-state current ≤ 10 µA) Indicators/settings Display elements LED PWR1 (termination board power supply), green LED LED PWR2 (termination board power supply), green LED Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 (industrial locations) Conformity Electromagnetic compatibility EN IEC 61326-3-2:2018 , NE 21:2017 For further information see system description. Degree of protection IEC 60529:2001 Ambient conditions Ambient temperature -20 ... 60 °C (-4 ... 140 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Degree of protection IP20 Connection Field side explosion hazardous area: 4 screw terminals per module , blue Control side non-explosion hazardous area: 50-pin Sub-D connector Supply pluggable screw terminals , black Fault output pluggable screw terminals , black Core cross-section screw terminals 0.25 ... 2.5 mm2 (24 ... 12 AWG) Material housing: polycarbonate, 10 % glass fiber reinforced Mass approx. 725 g Dimensions 216 x 200 x 163 mm (8.5 x 7.9 x 6.42 inch) , height including module assembly Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001 Data for application in connection with hazardous areas EU-type examination certificate CESI 06 ATEX 022 Marking 1 II (1)G [Ex ia Ga] IIC 1 II (1)D [Ex ia Da] IIIC 1 I (M1) [Ex ia Ma] I Non-hazardous area Maximum safe voltage 250 V (Attention! Um is no rated voltage.) Galvanic isolation Field circuit/control circuit safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 50303:2000 International approvals UL approval E106378 Control drawing 116-0327 IECEx approval IECEx certificate IECEx CES 06.0003 IECEx marking [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I General information Termination Board HiCTB16-TRX-RAC-PL-IO16 2 Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091 www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |