4 / 12 page ![]() DS1620 Table 3 describes the exact relationship of output data to measured temperature. . TEMPERATURE/DATA RELATIONSHIPS Table 3 TEMP DIGITAL OUTPUT (Binary) DIGITAL OUTPUT (Hex) +125˚C 0 11111010 00FA +25˚C 0 00110010 0032h +½˚C 0 00000001 0001h +0˚C 0 00000000 0000h -½˚C 1 11111111 01FFh -25˚C 1 11001110 01CEh -55˚C 1 10010010 0192h Higher resolutions may be obtained by reading the temperature, and truncating the 0.5°C bit (the LSB) from the read value. This value is TEMP_READ. The value left in the counter may then be read by issuing a READ COUNTER command. This value is the count remaining (COUNT_REMAIN) after the gate period has ceased. By loading the value of the slope accumulator into the count register (using the READ SLOPE command), this value may then be read, yielding the number of counts per degree C (COUNT_PER_C) at that temperature. The actual temperature may be then be calculated by the user using the following: TEMPERATURE=TEMP_READ-0.25 + C COUNT_PER_ IN) COUNT_REMA - _C (COUNT_PER OPERATION–THERMOSTAT CONTROLS Three thermally triggered outputs, THIGH, TLOW, and TCOM, are provided to allow the DS1620 to be used as a thermostat, as shown in Figure 3. When the DS1620’s temperature meets or exceeds the value stored in the high temperature trip register, the output THIGH becomes active (high) and remains active until the DS1620’s measured temperature becomes less than the stored value in the high temperature register, TH. The THIGH output can be used to indicate that a high temperature tolerance boundary has been met or exceeded, or it can be used as part of a closed loop system to activate a cooling system and deactivate it when the system temperature returns to tolerance. The TLOW output functions similarly to the THIGH output. When the DS1620’s measured temperature equals or falls below the value stored in the low temperature register, the TLOW output becomes active. TLOW remains active until the DS1620’s temperature becomes greater than the value stored in the low temperature register, TL. The TLOW output can be used to indicate that a low temperature tolerance boundary has been met or exceeded, or as part of a closed loop system it can be used to activate a heating system and deactivate it when the system temperature returns to tolerance. The TCOM output goes high when the measured temperature meets or exceeds TH, and will stay high until the temperature equals or falls below TL. In this way, any amount of hysteresis can be obtained. 4 of 12 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |