| 数据搜索系统,热门电子元器件搜索 |
|
VBM-CTR-K20-R2 数据表(PDF) 2 Page - Pepperl+Fuchs Inc. |
|
|
|||||||||||||||||||||||||||||
VBM-CTR-K20-R2 数据表(HTML) 2 Page - Pepperl+Fuchs Inc. |
|
2 / 2 page ![]() VBM-CTR-K20-R2 AS-Interface master Germany: +49 621 776 4411 Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com 2 Function The VBM-CTR-K20-R2 is a stand-alone mas- ter in AS-Interface specification 3.0 with IP20. The construction type is especially suited for use in a switch cabinet. Address allocation, acceptance of the target configuration and setting the baud rate can be managed via buttons. There are 7 LEDs on the front panel, showing the current status of the AS-Interface line. In the AS-Interface master with graphical dis- play the commissioning of the AS-Interface circuit and the test of the connected periphery devices can be separated completely overri- ding bus systems and from programming. The on-site operation via the graphic display and the four push buttons make it possible to show all of the functions on the display, which, for all other AS-Interface masters, are covered by the software AS-Interface control tools. PLC Functionality For PLC functionality the VBM-CTR-K20-R2 provides 16 kB program memory, 8 kB data memory, 1024 counters and 1024 timers. This is sufficient capacity to process all data arriving at the AS-Interface. The master can, therefore, also be operated as "stand-alone". The programm processing for 1000 word commands is approx. 2 ms. The program- ming language is based on STEP5. In the extended mode the AS-Interface CTRL func- tions (upload, download, start, stop, read and write marker) can be utilized. Accessories VAZ-SW-ACT32 Full version of the AS-I Control Tools in- cluding connection cable USB-0,8M-PVC ABG-SUBD9 Interface converter USB/RS 232 Matching system components VBG-RIO-KHD2-R2 Bus Coupler for Allen Bradley Remote I/O Technical data General specifications AS-Interface specification V3.0 PLC-Functionality integrated Earth fault detection EFD integrated EMC monitoring integrated Diagnostics function Extended function via display UL File Number E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters MTTFd 180 a at 30 °C Indicators/operating means Display Illuminated graphical LC display for addressing and error mes- sages LED RS 232 interface in operation; LED green LED AS-i ACTIVE AS-Interface operation normal; LED green LED CONFIG ERR configuration error; LED red LED PRG ENABLE autom. programming; LED green LED POWER voltage ON; LED green LED PRJ MODE projecting mode active; LED yellow LED U AS-i AS-Interface voltage; LED green Switch SET Selection and setting of a slave address OK button Mode selection traditional-graphical/confirmation Button MODE Mode selection PRJ-operation/save configuration/cursor ESC button Mode selection traditional-graphical/cancel Electrical specifications Insulation voltage Ui ≥ 500 V Rated operating voltage Ue from AS-Interface Rated operating current Ie ≤ 150 mA Interface Interface type RS 232 Transfer rate 1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600 or 11500 Bit/s , Automatic baud rate detection Cable length max. 30 m Connection AS-Interface spring terminals, removable Serial interfaces 9-pin Sub-D socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 62026-2:2013 Standard conformity Electromagnetic compatibility EN 61326 Degree of protection EN 60529:2000 AS-Interface EN 62026-2:2013 Ambient conditions Ambient temperature 0 ... 55 °C (32 ... 131 °F) Storage temperature -15 ... 75 °C (5 ... 167 °F) Mechanical specifications Degree of protection IP20 Mass 460 g Construction type Low profile housing , Stainless steel Approvals and certificates UL approval An isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over cur- rent protection is not required when a Class 2 source is emplo- yed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Notes In an AS-Interface network only one device can be operated earth fault detection. If there are many devices in an AS-Interface network, this can lead to the earth fault monitoring response threshold becoming less sensitive. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |