17 / 23 page ![]() Data Sheet ADP165/ADP166 Consider the case where a hard short from VOUT to ground occurs. At first, the ADP165/ADP166 limit current so that only 320 mA is conducted into the short. If self-heating of the junction temperature is great enough to cause its temperature to rise above 150°C, thermal shutdown activates, turning off the output and reducing the output current to zero. As the junction temperature cools and drops below 135°C, the output turns on and conducts 320 mA into the short, again causing the junction temperature to rise above 150°C. This thermal oscillation between 135°C and 150°C causes a current oscillation between 320 mA and 0 mA that continues as long as the short remains at the output. Current and thermal limit protections are intended to protect the device against accidental overload conditions. For reliable operation, device power dissipation must be externally limited so that junction temperatures do not exceed 125°C. THERMAL CONSIDERATIONS In most applications, the ADP165/ADP166 do not dissipate much heat due to their high efficiency. However, in applications with high ambient temperature and high supply voltage to output voltage differential, the heat dissipated in the package is high enough that it can cause the junction temperature of the die to exceed the maximum junction temperature of 125°C. When the junction temperature exceeds 150°C, the converter enters thermal shutdown. It recovers only after the junction temperature has decreased below 135°C to prevent any permanent damage. Therefore, thermal analysis for the chosen application is very important to guarantee reliable performance over all conditions. The junction temperature of the die is the sum of the ambient temperature of the environment and the temperature rise of the package due to the power dissipation, as shown in Equation 2. To guarantee reliable operation, the junction temperature of the ADP165/ADP166 must not exceed 125°C. To ensure that the junction temperature stays below this maximum value, the user must be aware of the parameters that contribute to junction temperature changes. These parameters include ambient temperature, power dissipation in the power device, and thermal resistances between the junction and ambient air (θJA). The θJA number is dependent on the package assembly compounds that are used and the amount of copper used to solder the package GND pins to the PCB. Table 10 shows the typical θJA values of the 5-lead TSOT, 6-lead LFCSP, and the 4-ball WLCSP for various PCB copper sizes. Table 11 shows the typical ΨJB value of the 5-lead TSOT, 6-lead LFCSP, and 4-ball WLCSP. Table 10. Typical θJA Values θJA (°C/W) Copper Size (mm2) TSOT LFCSP WLCSP 01 170 175.1 260 50 152 135.6 159 100 146 77.3 157 300 134 65.2 153 500 131 51 151 1 Device soldered to minimum size pin traces. Table 11. Typical ΨJB Values Package ΨJB Unit 5-Lead TSOT 42.8 (°C/W) 6-Lead LFCSP 17.9 (°C/W) 4-Ball WLCSP 58.4 (°C/W) Calculate the junction temperature of the ADP165/ADP166 from the following equation: TJ = TA + (PD × θJA) (2) where: TA is the ambient temperature. PD is the power dissipation in the die, given by PD = [(VIN − VOUT) × ILOAD] + (VIN × IGND) (3) where: VIN and VOUT are input and output voltages, respectively. ILOAD is the load current. IGND is the ground current. Power dissipation due to ground current is quite small and can be ignored. Therefore, the junction temperature equation simplifies to the following: TJ = TA + θJA[(VIN − VOUT) × ILOAD] (4) As shown in Equation 4, for a given ambient temperature, input- to-output voltage differential, and continuous load current, there exists a minimum copper size requirement for the PCB to ensure the junction temperature does not rise above 125°C. Figure 43 to Figure 57 show the junction temperature calculations for the different ambient temperatures, load currents, VIN-to-VOUT differentials, and areas of PCB copper. In the case where the board temperature is known, use the thermal characterization parameter, ΨJB, to estimate the junction temperature rise (see Figure 55 to Figure 57). Maximum junction temperature (TJ) is calculated from the board temperature (TB) and power dissipation (PD) using the following formula: TJ = TB + (PD × ΨJB) (5) The typical value of ΨJB is 17.9°C/W for the 6-lead LFCSP package, 42.8°C/W for the 5-lead TSOT package, and 58.4°C/W for the 4-ball WLCSP package. Rev. A | Page 17 of 23 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |