| 数据搜索系统,热门电子元器件搜索 |
|
VGS-150C 数据表(PDF) 2 Page - CUI INC |
|
|
|||||||||||||||||||||||||||||
VGS-150C 数据表(HTML) 2 Page - CUI INC |
|
2 / 5 page ![]() cui.com date 02/02/2022 │ page 2 of 5 CUI Inc │ SERIES: VGS-150C │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage ac input dc input 85 120 264 373 Vac Vdc frequency 47 63 Hz current at 115 Vac at 230 Vac 4 2 A A inrush current at 115 Vac, cold start at 230 Vac, cold start 30 60 A A leakage current at 240 Vac 0.75 mA no load power consumption 0.5 W OUTPUT parameter conditions/description min typ max units capacitive load 12 Vdc output 15 Vdc output 24 Vdc output 36 Vdc output 48 Vdc output 10,000 6,000 2,400 1,200 600 μF μF μF μF μF initial set point accuracy at full load ±1 % line regulation ±0.5 % load regulation 0%~100% load ±0.5 % adjustability built in trim pot ±10 % hold-up time at 115 Vac at 230 Vac 8 16 ms ms switching frequency 65 kHz temperature coefficient ±0.05 %/°C PROTECTIONS parameter conditions/description min typ max units over voltage protection 12 Vdc output, output shut-down, auto-recovery 15 Vdc output, output shut-down, auto-recovery 24 Vdc output, output shut-down, auto-recovery 36 Vdc output, output shut-down, auto-recovery 48 Vdc output, output shut-down, auto-recovery 16.2 21.75 33.6 48.6 60.0 Vdc Vdc Vdc Vdc Vdc over current protection auto-recovery 110 150 % short circuit protection hiccup, continuous, auto-recovery over temperature protection auto-recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to ground input to output output to ground 2,000 4,000 1,250 Vac Vac Vac safety approvals certified to: 62368: IEC/EN/UL designed to meet: 60335: IEC/EN designed to meet: 61558: IEC/EN designed to meet: 4943: GB safety class Class I EMI/EMC CISPR32/EN55032 Class B, IEC/EN61000-3-2 Class A (≤80% load) ESD IEC/EN 61000-4-2 Contact ±6KV /Air ±8KV, perf. Criteria A radiated immunity IEC/EN 61000-4-3 10V/m, perf. Criteria A EFT/burst IEC/EN 61000-4-4 ±4KV, perf. Criteria A surge IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV, perf. Criteria A conducted immunity IEC/EN61000-4-6 10 Vr.m.s, perf. Criteria A Additional Resources: Product Page | 3D Model |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |