21 / 29 page ![]() shorted together, but Cell 1 must always be populated. The designer can choose which cell inputs to leave unused. The example application circuits recommended are the most efficient configurations. At power-up, the part compares the voltage applied to each cell input with a nominal cell-detection threshold voltage of 0.7V. If the cell voltage is less than the cell- detection threshold, undervoltage detection is disabled for that cell input. If the voltage at the input is 0.7V or greater, undervoltage detection is specified by the state of the UVSEL_ inputs. Overvoltage detection is always enabled for all cell-voltage inputs. The cell-connection detection occurs just before the MAX11080/MAX11081 are fully functional as shown in Figure 12 under NUMBER OF CELLS DETECTED. TOPSEL Function The TOPSEL pin is used to indicate to a device whether it is the top device in the daisy-chain stack. The top daisy-chain device is responsible for generating the heartbeat signal at the top of the ALRM_ pin bus. This heartbeat propagates along the chain toward the host. To designate a device as the top device, the TOPSEL pin should be connected to VAA. For all other devices in a daisy-chain, this pin should be connected to AGND. The TOPSEL pin has a weak internal pulldown resistor, but this resistor should not be relied upon as the sole means of setting the TOPSEL logic level. The logic level of the TOPSEL pin is not latched internally at startup and is continuously sampled during operation. The ALRMU input should be connected to GNDU for the top module as good design practice to prevent noise pickup even though the input logic level is ignored. For a single device or DC-coupled daisy-chain applica- tion, the device can be operated in an alarm level mode instead of heartbeat mode by tying TOPSEL to AGND for all devices. In this mode of operation, ALRML passes the signal of ALRMU when the device is not in the alarm state. ALRML drives high when the device is in the alarm state. ALRMU must be tied to GNDU for the topmost device for this application. The following table summarizes the operation of TOPSEL and ALRML for level mode: Internal Self-Test The MAX11080/MAX11081 perform an internal self-test during power-up according to the linear regulator power-up flowchart (Figure 12). Each overvoltage com- parator is tested for the ability to detect an internally generated overvoltage test condition. This is done by using the ground voltage level as the threshold refer- ence in place of the usual threshold level. Figure 8 shows the connection for this test-mode compare level. If all comparators can detect the internally generated overvoltage test event, part operation continues. If any comparator fails to detect the internally generated over- voltage test event, a fault is signaled using the ALRML pin. The device must be power cycled to retest the comparators and attempt to clear this fault condition. Failure Mode and Effects Analysis High-voltage battery-pack systems can be subjected to severe stresses during in-service fault conditions and could experience similar conditions during the manufac- turing and assembly process. The MAX11080/MAX11081 are designed with high regard to these potential states. Open and short circuits at the package level must be readily detected for fault diagnosis and should be toler- ated whenever possible. A number of circuits are employed within the MAX11080/MAX11081 specifically to detect such conditions and progress to a known device state. Table 3 summarizes other conditions typi- cal in a normal manufacturing process along with their effect on the MAX11080/MAX11081 devices. See Table 4 for the FMEA analysis of the MAX11080/ MAX11081. If the cell voltage is within the monitor range, the heartbeat signal on ALRML resumes once the fault condition (either open or short) is removed, unless otherwise specified. 12-Channel, High-Voltage Battery-Pack Fault Monitors ______________________________________________________________________________________ 21 ALRML TOPSEL ALRMU No alarm Alarm 00 ALRMU 1 1X Heartbeat 1 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |