9 / 15 page ![]() CC2431 SWRS034 Page 9 of 14 2 4 6 8 10 12 14 45 50 55 60 65 70 75 80 85 90 95 10*log10(distance) Path Loss vs. log-distance for source 0x85, Z=2.1082. A=42.4103, n=2.9773 Figure 2: Path loss vs. log distance 2.1.2.1.4 RSSI Values The RSSI values are the RSSI measurements corresponding to the set of reference coordinates. The RSSI values are within the interval [-40 dBm, -95 dBm] with precision 0.5 dBm. The negative sign is removed in the value written. As an example, in the case where the value RSSI = -50.35 dB, this would be written into the location engine as 50.5. Note that a value of 0.0 must be written as RSSI value for unused reference coordinates. The engine will not function correctly if only some of the parameters are loaded. 2.1.2.2 Loading Parameters All measured parameters are loaded into the RF register MEASPARM. Before writing to MEASPARM, a 1 must be written to the register bit LOCENG.PARLD to indicate that a set of measured parameters are being written. Once the parameter load process commences ( LOCENG.PARLD =1), all ten parameters must be written. The measured parameters must be written in the order [A, n, rssi0, rssi1, … rssi7] to the MEASPARM register. Once the parameter load process commences ( LOCENG.PARLD =1) it must be completed. Eight RSSI values must be written, so any unused slots must be written as zeros. After all ten parameters have been written, a 0 must be written to the register bit LOCENG.PARLD. 2.1.3 Location Estimation The estimated location coordinates are given in meters in the interval [0.0, 63.5] with precision 0.5 m. The data format uses the LSB bit as the fractional part. When reference coordinates and measured parameters have been loaded, the location estimate is calculated by writing 1 to the LOCENG.RUN register bit. The estimated coordinates can be read from the LOCX and LOCY registers when LOCENG.DONE is set to 1. This occurs 1200 system clock cycles (16/32 MHz) after LOCENG.RUN was set to 1. The Location Engine does not produce any interrupt requests. The estimated coordinates remain valid in the LOCX and LOCY registers until new |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |