| 数据搜索系统,热门电子元器件搜索 |
|
ATLS100MA103 数据表(PDF) 3 Page - Analog Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
ATLS100MA103 数据表(HTML) 3 Page - Analog Technologies, Inc. |
|
3 / 15 page ![]() 1161 Ringwood Ct, #110, San Jose, CA 95131, U. S. A. Tel.: (408) 748-9100, Fax: (408) 770-9187 www.analogtechnologies.com Copyrights 2000-2022, Analog Technologies, Inc. All Rights Reserved. Updated on 3/7/2022 Email: staff@analogti.com/sales@analogti.com 3 Analog Technologies ATLS100MA104 Low Noise Constant Current Laser Controller SPECIFICATIONS Table 2. Characteristics (TAmbient = 25 °C) Parameter Value Unit/Note Maximum Output Current 100 mA Peak-to-Peak Noise @ 0.1Hz ~ 10Hz, VVPS=5V, Rs=1Ω, VOUT=3V, IOUT=100mA 3.96 μAP-P Current Noise Density @ 0.1Hz ~ 10Hz, VVPS=5V, Rs=1Ω, VOUT=3V, IOUT=100mA 0.6 µARMS Current Set Voltage Range (VLIS) 0 ~ 2.5 V Current Limit Set Voltage Range (VLIMS) 0 ~ 2.75 V Rise and Fall Times of large signal 75 nS Rise and Fall Times of small signal 46 nS Bandwidth of large signal (0.2V ~ 2.2V square wave) 4.67 MHz Bandwidth of small signal (1V DC plus 200mV AC square wave) 7.61 MHz Minimum Drop Out Voltage 0.9 + 5 ×IOUT V Power Supply Voltage Range 3.1 ~ 5.5 V Operating Case Temperature −40 ~ 85 °C Storage temperature −55 ~ 150 °C High IOUT Absolute Accuracy (T = −30ºC ~ 60ºC) <±0.5 mA High IOUT Stability (the load can be made of 1 to 5 diodes) <±0.5 mA Figure 3. Input Control OPERATION PRINCIPLE The block diagram of the controller is shown in Figure 4. The shutdown control circuit is activated under one of these 3 circumstances: external shut down, output current exceeds the current limit, and the internal temperature exceeds 120 °C. When the controller is shut down by the external shutdown signal, it will restart upon detecting the releasing of the shutdown signal. When it is shut down by the over current limit, the controller shuts down itself and restarts again by going through the soft- start process immediately. Therefore, the output current has a saw-tooth waveform: quick shut down, slow and ramp up. When the controller is shut down by the over temperature, it will wait till the temperature goes below the temperature limit, 120 °C. Usually it takes a few or tens of seconds for the controller to cool down before it restarts itself, depending on the thermal mass of the controller and its surrounding mechanical parts attached thermally, such as the PCB and its traces, the heat-sinks if any, etc. When controller is shut down, the voltage reference is also shut down. Figure 4. Block Diagram |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |