| 数据搜索系统,热门电子元器件搜索 |
|
ADP5588ACPZ-R7 数据表(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP5588ACPZ-R7 数据表(HTML) 22 Page - Analog Devices |
|
22 / 28 page ![]() ADP5588 Data Sheet Rev. D | Page 22 of 28 Table 39. CMP_CONFG_SENS2—Register 0x32 (Sensor 2 Comparator Configuration Register) Field Bit Description [7:6] Not used. FILT (2-0) [5:3] Programs the number of consecutive measurements required to transition the L2 and L3 levels. FILT Number Required Approximate Time (sec) 000 1 0.08 001 2 0.16 010 4 0.32 011 8 0.64 100 16 1.28 101 32 2.56 110 64 5.12 111 128 10.24 FORCE_RD 2 1: Forces a read of the light sensor; reset by the internal state machine after conversion is complete and L2_OUT and L3_OUT are valid.1 L3_EN 1 1: Enables the L3 comparator for Sensor 2 input. 0: Disables the L3 comparator for Sensor 2 input. L2_EN 0 1: Enables the L3 comparator for Sensor 2 input. 0: Disables the L3 comparator for Sensor 2 input. Note that the L3 comparator has priority over the L2 comparator. 1 When the software forces a conversion, the state machine clears the forced bit after the conversion is complete and the proper registers have been updated. Table 40. CMP1_LVL2_TRIP—Register 0x33 (L2 Light Sensor Reference Level (Output Falling for Sensor 1) Field Bit Description L2_T7 to L2_T0 [7:0] Sensor 1 comparator Level 2 (Office) reference. If the comparator input is below this trip point, the comparator trips and enters Level 2 (office) mode and L2_OUT is set. The programmable range is from 0 μA to 1000 μA (0 lux to 2550 lux) in steps of 4 μA. Table 41. CMP1_LVL2_HYS—Register 0x34 (L2 Light Sensor Hysteresis (Active When Output Rising) for Sensor 1) Field Bit Description L2_H7 to L2_H0 [7:0] Sensor 1 comparator Level 2 (Office) hysteresis. If the comparator input is above L2_TRP + L2_HYS, the comparator trips and enters Level 1 (outdoor) mode and L2_OUT is cleared. The programmable range is from 0 μA to 1000 μA (0 lux to 2550 lux) in steps of 4 μA. Table 42. CMP1_LVL3_TRIP—Register 0x35 (L3 Light Sensor Reference Level (Output Falling for Sensor 1) Field Bit Description L3_T7 to L3_T0 [7:0] Sensor 1 comparator Level 3 (Dark) reference. If the comparator input is below L3_TRP, the comparator trips and enters Level 3 (dark) mode and L3_OUT is set. The programmable range is from 0 μA to 127.5 μA (0 lux to 318.75 lux) in steps of 0.5 μA. Table 43. CMP1_LVL3_HYS—Register 0x36 (L3 Light Sensor Hysteresis (Active When Output Rising) for Sensor 1) Field Bit Description L3_H [7:0] Sensor 1 comparator Level 3 (Dark) hysteresis. If the comparator input is above L3_TRP + L3_HYS, the comparator trips and enters Level 2 (office) mode and L3_OUT is cleared. The programmable range is from 0 μA to 127.5 μA (0 lux to 318.75 lux) in steps of 0.5 μA. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |