| 数据搜索系统,热门电子元器件搜索 |
|
DVR21 数据表(PDF) 114 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
DVR21 数据表(HTML) 114 Page - Microchip Technology |
|
114 / 416 page ![]() PIC24FJ256GA705 FAMILY DS30010118D-page 114 2016-2018 Microchip Technology Inc. 10.2.2 IDLE MODE Idle mode has these features: • The CPU will stop executing instructions. • The WDT is automatically cleared. • The system clock source remains active. By default, all peripheral modules continue to operate normally from the system clock source, but can also be selectively disabled (see Section 10.4 “Selective Peripheral Module Control”). • If the WDT or FSCM is enabled, the LPRC will also remain active. The device will wake from Idle mode on any of these events: • Any interrupt that is individually enabled. • Any device Reset. • A WDT time-out. On wake-up from Idle, the clock is reapplied to the CPU and instruction execution begins immediately, starting with the instruction following the PWRSAV instruction or the first instruction in the ISR. 10.2.3 INTERRUPTS COINCIDENT WITH POWER SAVE INSTRUCTIONS Any interrupt that coincides with the execution of a PWRSAV instruction will be held off until entry into Sleep or Idle mode has completed. The device will then wake-up from Sleep or Idle mode. 10.2.4 LOW-VOLTAGE RETENTION REGULATOR PIC24FJ256GA705 family devices incorporate a second on-chip voltage regulator, designed to provide power to select microcontroller features at 1.2V nomi- nal. This regulator allows features, such as data RAM and the WDT, to be maintained in power-saving modes where they would otherwise be inactive, or maintain them at a lower power than would otherwise be the case. Retention Sleep uses less power than standard Sleep mode, but takes more time to recover and begin execu- tion. An additional 10-15 µs (typical) is required to charge VCAP from 1.2V to 1.8V and start to execute instructions when exiting Retention Sleep. The VREGS bit allows control of speed to exit from the Sleep modes (regular and Retention) at the cost of more power. The regulator band gaps are enabled, which increases the current but reduces time to recover from Sleep by ~10 µs. The low-voltage retention regulator is only available when Sleep mode is invoked. It is controlled by the LPCFG Configuration bit (FPOR<2>) and in firmware by the RETEN bit (RCON<12>). LPCFG must be programmed (= 0) and the RETEN bit must be set (= 1) for the regulator to be enabled. 10.2.5 EXITING FROM LOW-VOLTAGE RETENTION SLEEP All of the methods for exiting from standard Sleep also apply to Retention Sleep (MCLR, INT0, etc.). However, in order to allow the regulator to switch from 1.8V (oper- ating) to Retention mode (1.2V), there is a hardware ‘lockout timer’ from the execution of Retention Sleep until Retention Sleep can be exited. During the ‘lockout time’, the only method to exit Reten- tion Sleep is a POR or MCLR. Interrupts that are asserted (such as INT0) during the ‘lockout time’ are masked. The lockout timer then sets a minimum interval from when the part enters Retention Sleep until it can exit from Retention Sleep. Interrupts are not ‘held pending’ during lockout; they are masked and in order to exit after the lockout expires, the exiting source must assert after the lockout time. The lockout timer is derived from the LPRC clock, which has a wide (untrimmed) frequency tolerance. The lockout time will be one of the following two cases: • If the LPRC was not running at the time of Retention Sleep, the lockout time is 2 LPRC periods + LPRC wake-up time • If the LPRC was running at the time of Retention Sleep, the lockout time is 1 LPRC period Refer to Table 32-20 and Table 32-21 in the AC Electrical Specifications for the LPRC timing. 10.2.6 SUMMARY OF LOW-POWER SLEEP MODES The RETEN bit and the VREGS bit (RCON<12,8>) allow for four different Sleep modes, which will vary by wake-up time and power consumption. Refer to Table 10-1 for a summary of these modes. Specific information about the current consumption and wake times can be found in Section 32.0 “Electrical Characteristics”. TABLE 10-1: LOW-POWER SLEEP MODES RETEN VREGS MODE Relative Power 0 1 Sleep A Few μA Range 0 0 Fast Wake-up 100 μA Range 1 1 Retention Sleep Less than 1 μA 1 0 Fast Retention A Few μA Range |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |