17 / 22 page ![]() www.sensirion.com Version 1.1 – April 2021 17/22 3.10 Low power single shot (SCD41) In addition to periodic measurement modes, the SCD41 features a single shot measurement mode, i.e. allows for on-demand measurements. The typical communication sequence is as follows: 1. The sensor is powered up. 2. The I2C master sends a single shot command and waits for the indicated max. command duration time. 3. The I2C master reads out data with the read measurement sequence (chapter 3.5.2). 4. Steps 2-3 are repeated as required by the application. To reduce noise levels, the I2C master can perform several single shot measurements in a row and average the CO2 output values. After a power cycle, the initial two single shot readings should be discarded to maximize accuracy. The idle current in between measurements is 0.15 mA (typ.), respectively 0.2 mA (max.). The energy consumed per single shot typically is 243 mJ (296 mJ max.). As for the periodic measurement modes, the automatic self-calibration (ASC) is enabled per default in single shot operation. The automatic self-calibration is optimized for single shot measurements performed every 5 minutes. Longer measurement intervals will result in less frequent self-calibration sequences. Note that no self-calibration is issued if the sensor is power-cycled between single shot measurements Please consult Chapter 3.7 for a detailed description of the automatic-self calibration and the corresponding commands. 3.10.1 measure_single_shot Description: On-demand measurement of CO2 concentration, relative humidity and temperature. The sensor output is read using the read_measurement command (chapter 3.5.2). Table 28: measure_single_shot I2C sequence description Write (hexadecimal) Input parameter: - Response parameter: - Max. command duration [ms] length [bytes] signal conversion length [bytes] signal conversion 0x219d - - - - 5000 Example: measure single shot Write 0x219d (hexadecimal) Command 3.10.2 measure_single_shot_rht_only Description: On-demand measurement of relative humidity and temperature only. The sensor output is read using the read_measurement command (chapter 3.5.2). CO2 output is returned as 0 ppm. Table 29: measure_single_shot_rht_only I2C sequence description Write (hexadecimal) Input parameter: - Response parameter: - Max. command duration [ms] length [bytes] signal conversion length [bytes] signal conversion 0x2196 - - - - 50 Example: measure single shot, RH and T output only Write 0x2196 (hexadecimal) Command |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |