| 数据搜索系统,热门电子元器件搜索 |
|
G9KB 数据表(PDF) 2 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
G9KB 数据表(HTML) 2 Page - Omron Electronics LLC |
|
2 / 5 page ![]() 2 G9KB PCB Power Relays G 9 K B Characteristics Note. The values given above are initial values at 23°C. (except electrical durability) *1. Measurement conditions: 6 VDC, 20 A (after 30 seconds) voltage drop method. *2. Measurement conditions: Applied rated coil voltage, no contact bouncing. *3. Measurement conditions: Measured with a 1,000 VDC megohmmeter at the same point as the dielectric strength was measured. *4. This specification is when diode and zener diode are used. For relay coil, please connect diode and zener diode. For more detail, please refer to Diode Connection for Operating Coil on page 4. *5. The humidity range of 25% to 75% conforms to the environmental conditions of JIS C 5442. Also, refer to Relay Service Life on page 5. *6. The value was measured at a switching frequency of 180 operations/ minute. *7. For the detail regarding holding voltage usage, please refer to Coil Voltage Reduction (Holding Voltage) after Relay Operation on page 4. Malfunction shock resistance Item Model G9KB-1A Contact resistance *1 5 m Ω max. Operate time *2 30 ms max. Release time *2 10 ms max. Insulation resistance *3 1,000 M Ω min. Dielectric strength Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 2,500 VAC, 50/60 Hz for 1 min Impulse withstand voltage Between coil and contacts 10 kV (1.2 × 50 μs) Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction Excitation: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) No excitation: 10 to 55 to 10 Hz, 1.5 mm single amplitude (0.3 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction Excitation: 100 m/s2 No excitation: 50 m/s2 Durability Mechanical 1,000,000 operations min. (at 10,800 operations/h) Electrical (Resistive) *4 (1) 600 VDC 50 A 2,000 operations min. (Switching frequency: 1 second ON - 9 seconds OFF at 85°C and 25% to 75% RH) *5 (2) 600 VDC 1 A 100,000 operations min. (Switching frequency: 1 second ON - 9 seconds OFF at 85°C and 25% to 75% RH) *5 Failure rate (P level) (Reference value) *6 1 A at 5 VDC Use conditions Coil holding voltage *7 45% to 60% of rated coil voltage Ambient operating temperature -40°C to 85°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 110 g 1,000 Z+ X+ Y- Z- X- Y+ 1,000 1,000 1,000 600 800 200 400 1,000 1,000 No Excitation Excitation Contact terminal Coil terminal Shock direction Measurement: Measure the value of contact malfunction happening by applying 3 axes with 6 direction 3 times each. The energized voltage is within the range of the rated holding voltage. Standard value: Excitation 100 m/s2 No excitation 50 m/s2 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |