2 / 16 page ![]() PJA-2 PJA100F AC-DC Power Supplies Enclosed Type PJ A 100 F -O -O Ordering information 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *6 C : with Coating R : Remote on/off (Required external power source) J : EP (Tyco Electronics) connector type J1 : VH (J.S.T.) connector type T : Vertical terminal block N2: with DIN rail See 6.1 in Instruction Manual. R 1 2 3 4 5 6 SPECIFICATIONS MODEL PJA100F-12 PJA100F-15 PJA100F-24 PJA100F-36 PJA100F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to “Derating” and instruction manual 1.1, 3) CURRENT[A] ACIN 100V 1.2typ (Io=90%) ACIN 115V 1.1typ (Io=100%) ACIN 230V 0.6typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 82typ (Io=90%) 83typ (Io=90%) 85typ (Io=90%) 86typ (Io=90%) 86typ (Io=90%) ACIN 115V 82typ (Io=100%) 83typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) ACIN 230V 85typ (Io=100%) 86typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) POWER FACTOR ACIN 100V 0.98typ (Io=90%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.90typ (Io=100%) * Power factor correction is stopped at AC250V or more. INRUSH CURRENT[A] ACIN 100V 16typ (Io=90%) Ta=25C at cold start ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) OUTPUT VOLTAGE[V] 12 15 24 36 48 CURRENT[A] ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”) ACIN 115V-264V 8.4 6.7 4.3 2.8 2.1 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”) ACIN 115V-264V 100.8 100.5 103.2 100.8 100.8 LINE REGULATION[mV] *3 48max 60max 96max 144max 192max LOAD REGULATION [mV] *3 Io=30 to 100% 100max 120max 150max 150max 300max Io=0 to 30% Burst operation (Please contact us about detail) RIPPLE[mVp-p] *1 Io: load factor 0 to +40C 120max 120max 120max 150max 150max -10 to 0C 160max 160max 160max 200max 400max Io=0 to 30% 500max 500max 500max 500max 500max RIPPLE NOISE[mVp-p] *1 Io: load factor 0 to +40C 150max 150max 150max 200max 200max -10 to 0C 180max 180max 180max 240max 500max Io=0 to 30% 600max 600max 600max 600max 600max TEMPERATURE REGULATION[mV] 0 to +40C 120max 150max 240max 360max 480max -10 to +40C 180max 180max 290max 440max 600max DRIFT[mV] *2 48max 60max 96max 144max 192max START-UP TIME[ms] 500typ (ACIN 115V, Io=100%) Ta=25C HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 OUTPUT VOLTAGE SETTING[V] 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION[V] 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *8 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *8 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *8 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATINGTEMP.,HUMID.AND ALTITUDE *4 -20 to +70C (Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *7 Complies with IEC61000-3-2 class A *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. Example recommended EMI/EMC filter NAC-04-472 * Please consider "PBA100F-5-N" about 5V output with case cover. *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series June 25, 2020 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |