| 数据搜索系统,热门电子元器件搜索 |
|
PJA600F-15-R 数据表(PDF) 6 Page - COSEL CO., LTD. |
|
|
|||||||||||||||||||||||||||||
PJA600F-15-R 数据表(HTML) 6 Page - COSEL CO., LTD. |
|
6 / 16 page ![]() PJA-6 PJA300F AC-DC Power Supplies Enclosed Type Ordering information 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *6 C : with Coating G: Low leakage current V : External potentiometer for output voltage adjustment R : Remote on/off (Required external power source) F4: Low speed fan See 6.1 in Instruction Manual. R PJ A 300 F -O -O 1 2 3 4 5 6 SPECIFICATIONS MODEL PJA300F-5 PJA300F-12 PJA300F-15 PJA300F-24 PJA300F-36 PJA300F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 100V. Refer to “Derating” and instruction manual 1.1, 3) CURRENT[A] ACIN 100V 3.5typ (Io=100%) 3.9typ (Io=100%) ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%) ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 73typ (Io=100%) 79typ (Io=100%) 81typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) 82typ (Io=100%) ACIN 115V 74typ (Io=100%) 80typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) 83typ (Io=100%) 83typ (Io=100%) ACIN 230V 77typ (Io=100%) 82typ (Io=100%) 84typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 86typ (Io=100%) POWER FACTOR ACIN 100V 0.99typ (Io=100%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20typ (Io=100%) Ta=25C at cold start ACIN 115V 20typ (Io=100%) Ta=25C at cold start ACIN 230V 40typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) OUTPUT VOLTAGE[V] 5 12 15 24 36 48 CURRENT[A] ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”) ACIN 100V-264V 50 25 20 12.5 8.4 6.3 WATTAGE[W] ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”) ACIN 100V-264V 250 300 300 300 302.4 302.4 LINE REGULATION[mV] *3 20max 48max 60max 96max 144max 192max LOAD REGULATION[mV] *3 40max 100max 120max 150max 150max 300max RIPPLE[mVp-p] *1 0 to +50C 80max 120max 120max 120max 150max 150max -10 to 0C 140max 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] *1 0 to +50C 120max 150max 150max 150max 200max 200max -10 to 0C 160max 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0 to +50C 50max 120max 150max 240max 360max 480max -10 to +50C 75max 180max 180max 290max 440max 600max DRIFT[mV] *2 20max 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 OUTPUT VOLTAGE SETTING[V] 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION[V] 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *9 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *9 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *9 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATINGTEMP.,HUMID.AND ALTITUDE *4 -20 to +70C (Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A Example recommended EMI/EMC filter NAC-06-472 *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series June 25, 2020 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |