| 数据搜索系统,热门电子元器件搜索 |
|
L9918 数据表(PDF) 10 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9918 数据表(HTML) 10 Page - STMicroelectronics |
|
10 / 109 page ![]() • Current limitation enabled accordingly to current limitation thresholds provided by LIN or by NVM registers contents (the lower between the two current limitation thresholds is adopted). • Safety functions active. • Thermal compensation enabled. • Low voltage function. 1.5.5 Regulation default This mode is equivalent to the LIN regulation mode except that, being without LIN communication, NVM default regulation parameters (VBSPDEF, TFLRCup, TFLRCdw, SPLRC) are used for regulation. Regulation default can be entered from wake-up state when phase rotation is greater than SPSS (N_NOTSTART NVM register). Phase amplitude required to enter regulation default depends on KLV_AC_ADAP_MIN_NOT, KLV_AC_ADAP_MIN and ACADAPMIN_MODE NVM registers. Regulation default can be entered from LIN regulation state in case no valid frame is provided for a time longer than tLIN_COM, adopted set point changes from VBSPLINRG to VBSPDEF. Set point transition to default VBSPDEF is performed with a ramp of VBSP_LDslope and excitation current limitation moves to IFELD_MAXB or I_MAX with a ramp of IFLIM_LDslope. If LIN communication resumes, regulation voltage and current limitation target change immediately, accordingly to the received RX frame data. In regulation default state: • LRC function enabled accordingly with NVM selection. • Phase regulation enabled. • Current limitation set to IFELD_MAXB and I_MAX. • Safety function enabled. • Thermal compensation enabled. • Low voltage function. 1.5.6 Safety Safety state is an excitation OFF state which is entered as soon as a safety protection mechanism is activated while device is into pre-excitation or regulation state. Here below a list of the safety mechanisms implemented by L9918: 1.5.6.1 Current protection In all the states where the excitation power MOS is active, overcurrent protection function is working. As soon as the IFOCP threshold is reached the power is switched OFF. 1.5.6.2 Thermal protection In case TJ reaches the Tsd,x threshold (selectable by NVM bits THERMAL_TH_SEL), EXC power MOS is switched OFF till the TJ temperature decrease below Tsd,x - Tsdhy. 1.5.6.3 Overvoltage safety protection In case of B+ > VBOV_safetyL for more than TOVflt_safetyL or B+ > VBOV_safetyH for more than TOVflt_safetyH, EXC power MOS is switched OFF till B+ returns at a value lower than VBOV_safetyL for more than TOVflt_safetyL time. L9918 State diagram DS13000 - Rev 2 page 10/109 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |