21 / 48 page ![]() DS12813 Rev 2 21/48 PM8805 PM8805 overview 48 The new 4-pair PoE standard defines two extra PD and PSE types. Type3 identifies a PSE delivering up to 60 W, and Type4 a PSE up to 99.9 W over 4-pair. The same types are defined for single-signature PDs, where the allocated power depends on the assigned class, which is the result of the Multiple-Event Classification, summarized in Table 7. The assigned class may be different from the requested class for two reasons: the PSE Type is lower than the PD Type, or the PSE doesn't have enough power to allocate the PD request. Anyway, if the PSE cannot afford the PD full power, it only issues a number of Class Events compatible with the maximum available power, and the PD has to comply with that. To do that, the PM8805 provides the system with the indication of the number of Class Events detected through the T0, T1, T2 outputs. See Section 4.12 for more details. The PM8805 is capable of covering all Single-Signature PD Types and Classes. As a Type1-2 PD, the PM8805 presents a class 0-4 current within the classification range of 14.5 V to 20.5 V using the CLS1 pin during the first two Class Events. From the 3rd Class Event onwards, the CLS2 pin is activated, so it is possible to set the new classes defined for Type 3 and 4 PDs. The detailed behavior of the controller during classification is depicted in Figure 5: Above the mark range, with voltage rising above Von_class for the first time, the CLS1 buffer is turned on with a Td_cls delay (3.3 ms typ). Then a Tcls_typ3 timer (81 ms typ) starts, in order to detect the length of the first Class Event. The CLS1 buffer stays on until the input voltage falls below the mark threshold Vmark_th or rises above Voff_class. When the voltage falls to mark range, the internal timer is stopped and stored, and a Class Event counter is increased. If the Tcls_typ3 time has expired, the first long Class Event is acknowledged, identifying that PSE is Type3 or Type4, thus allowing the PM8805 to set the MPS timings accordingly. See 4.13 for more details on MPS. When the input voltage re-enters the class range after staying into mark, the CLS1 behavior is the same as before, while the timer is not used anymore. After the third transition into the mark range, entering into class, the CLS2 buffer is turned on instead of CLS1, as always after Td_cls. The behavior in the following Mark and Class Events is always the same as the third one, regardless of the number of pulses provided by the PSE. Both CLS1 and CLS2 are turned off if the input voltage exceeds Voff_Class (23 V typ.). The Classification ends when the PD voltage rises above Vuvlo_rising, or falls below the reset threshold (Vrst_cls). In the first case the number of Class Events stored in the counter determines the values of the T0, T1, T2 outputs, as described in Table 13 PM8805 Type Signals description table. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |