  VL53L4CX Datasheet HTML 1Page - STMicroelectronics VL53L4CX Datasheet HTML 2Page - STMicroelectronics VL53L4CX Datasheet HTML 3Page - STMicroelectronics VL53L4CX Datasheet HTML 4Page - STMicroelectronics VL53L4CX Datasheet HTML 5Page - STMicroelectronics VL53L4CX Datasheet HTML 6Page - STMicroelectronics VL53L4CX Datasheet HTML 7Page - STMicroelectronics VL53L4CX Datasheet HTML 8Page - STMicroelectronics VL53L4CX Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 38 page
background image
1.4
Application schematic
The following figure shows the application schematic of the VL53L4CX.
Figure 3. VL53L4CX schematic
Capacitors on external supply AVDD should be placed as close as possible to the AVDDVCSEL and AVSSVCSEL
module pins.
External pull up resistor values can be found in I2C-bus specification. Pull-ups are typically fitted only once per
bus, near the host. For suggested values see Table 3. Suggested pull-up and series resistors for I²C fast mode
and Table 4. Suggested pull-up and series resistors for I²C fast mode plus.
XSHUT pin must always be driven to avoid leakage current. A pull-up is needed if the host state is not known.
XSHUT is needed to use hardware standby mode (no I²C communication).
XSHUT and GPIO1 pull-up recommended values are 10 kOhms.
GPIO1 should be left unconnected if not used.
The following tables list recommended values for pull-up and series resistors for an AVDD of 1.8 V to 2.8 V in I²C
fast mode (up to 400 kHz) and fast mode plus (up to 1 MHz).
Table 3. Suggested pull-up and series resistors for I²C fast mode
I²C load capacitance (CL)(1)
Pull up resistor (Ohms)
Series resistor (Ohms)
CL ≤ 90 pF
3.6 k
0
90 pF < CL ≤ 140 pF
2.4 k
0
140 pF < CL ≤ 270 pF
1.2 k
0
270 pF < CL ≤ 400 pF
0.8 k
0
1. For each bus line, CL is measured in application PCB by customer.
VL53L4CX
Application schematic
DS13805 - Rev 3
page 5/38



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com