11 / 15 page ![]() Data Sheet AD8417-2 OUTPUT OFFSET ADJUSTMENT analog.com Rev. 0 | 11 of 15 The output of the AD8417-2 can be adjusted for unidirectional or bidirectional operation. UNIDIRECTIONAL OPERATION Unidirectional operation allows the AD8417-2 to measure currents through a resistive shunt in one direction. The basic modes for unidirectional operation are ground referenced output mode and VS referenced output mode. For unidirectional operation, the output can be set at the negative rail (near ground) or at the positive rail (near VS) when the differen- tial input is 0 V. The output moves to the opposite rail when a correct polarity differential input voltage is applied. The required polarity of the differential input depends on the output voltage setting. If the output is set at the positive rail, the input polarity must be negative to decrease the output. If the output is set at ground, the polarity must be positive to increase the output. Ground Referenced Output Mode When using the AD8417-2 in ground referenced output mode, both referenced inputs are tied to ground, which causes the output to sit at the negative rail when there are zero differential volts at the input (see Figure 27). Figure 27. Ground Referenced Output VS Referenced Output Mode VS referenced output mode is set when both reference pins are tied to the positive supply. It is typically used when the diagnostic scheme requires detection of the amplifier and the wiring before power is applied to the load (see Figure 28). Figure 28. VS Referenced Output BIDIRECTIONAL OPERATION Bidirectional operation allows the AD8417-2 to measure currents through a resistive shunt in two directions. In this case, the output is set anywhere within the output range. Typically, it is set at half scale for equal range in both directions. In some cases, however, it is set at a voltage other than half scale when the bidirectional current is nonsymmetrical. Apply voltage(s) to the referenced inputs to adjust the output. VREF1 and VREF2 are tied to internal resistors that connect to an internal offset node. There is no operational difference between the pins. EXTERNAL REFERENCED OUTPUT Tying both pins together and to a reference produces an output equal to the reference voltage when there is no differential input (see Figure 29). The output decreases the reference voltage when the input is negative, relative to the −IN pin, and increases when the input is positive, relative to the −IN pin. Figure 29. External Referenced Output |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |