| 数据搜索系统,热门电子元器件搜索 |
|
LMA 数据表(PDF) 2 Page - COSEL CO., LTD. |
|
|
|||||||||||||||||||||||||||||
LMA 数据表(HTML) 2 Page - COSEL CO., LTD. |
|
2 / 10 page ![]() LMA-2 LMA100F AC-DC Power Supplies Medical Type LM A 100 F -O -O Ordering information R 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G: Low leakage current H : with the function to be acceptable to output peak current J1: VH(J.S.T.)connector type R : with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover P :Setting in the overcurrent protection rating This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL LMA100F-24-Y LMA100F-24-HY MAX OUTPUT WATTAGE[W] 103.2 103.2 (206.4) *2 DC OUTPUT 24V 4.3A 24V 4.3A (8.6A) *2 SPECIFICATIONS MODEL LMA100F-24-Y LMA100F-24-HY INPUT VOLTAGE[V] AC85 - 264 1f (Refer to “Derating” ,Instruction Manual 1 and 3) CURRENT[A] ACIN 100V 1.4typ (Io=100%) ACIN 200V 0.7typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 84.0typ (Io=100%) 84.0typ (Io=100%) ACIN 200V 86.0typ (Io=100%) 86.0typ (Io=100%) POWER FACTOR ACIN 100V 0.99typ (Io=100%) ACIN 200V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.10 / 0.25max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) OUTPUT VOLTAGE[V] 24 24 CURRENT[A] 4.3 4.3 (Peak 8.6) *2 LINE REGULATION[mV] *7 96max 96max LOAD REGULATION[mV] *7 150max 150max RIPPLE[mVp-p] *3 0 to +50C 120max 120max -10 - 0C 160max 160max RIPPLE NOISE[mVp-p]*3 0 to +50C 150max 150max -10 - 0C 180max 180max TEMPERATURE REGULATION[mV] 0 to +50C 240max 240max -10 to +50C 290max 290max DRIFT[mV] *4 96max 96max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUTVOLTAGE ADJUSTMENT RANGE[V] 19.20 to 27.50 19.20 to 27.50 OUTPUT VOLTAGE SETTING[V] 24.00 to 24.96 24.00 to 24.96 PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically OVERVOLTAGE PROTECTION[V] 27.60 to 33.60 27.60 to 33.60 OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Option (Required external power source.) ISOLATION INPUT-OUTPUT.RC *6 AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOOP INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOOP OUTPUT.RC-FG *6 AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) OUTPUT-RC *6 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) ENVIRONMENT OPERATINGTEMP.,HUMID.AND ALTITUDE *5 -10 to +70C, 20 - 90%RH (Non condensing), (Refer to “Derating”, Instruction Manual 3) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS (AT ONIY AC input) ANSI/AAMI ES60601-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed. CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 OTHERS CASE SIZE/WEIGHT 62X33X155mm [2.44X1.30X6.10 inches] (WXHXD) / 290g max (with chassis & cover : 470g max) COOLING METHOD Convection (Refer to “Derating”, Instruction Manual 3) *5 *1 Specification is changed at option, refer to Instruction Manual. *2 Peak loading for 10sec. And Duty 40% max. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. *3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *5 Derating is required. *6 Applicable when remote control (optional) is added. *7 Please contact us about dynamic load and input response. *8 Please contact us about another class. * To meet the specifications. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Example recommended EMI/EMC filter NAM-04-101 *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series June 29, 2020 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |