| 数据搜索系统,热门电子元器件搜索 |
|
B7AH-R6D53 数据表(PDF) 52 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
B7AH-R6D53 数据表(HTML) 52 Page - Omron Electronics LLC |
|
52 / 121 page ![]() G70D-B7A G70D-B7A 50 Precautions General Electric Shock Do not touch charged parts of relay terminals or socket terminals while power is supplied. Doing so may result in electric shock. Wiring Be sure to turn the power OFF before performing wiring. Do not touch the terminal block while power is supplied unless the cover is mounted. Doing so may result in electric shock. Be sure to apply the specified voltage to input terminals. Applying an incorrect voltage may prevent the product from operating with its rated performance characteristics, or may cause damage or burn- ing. Relay Models Do not use the product for loads that exceed the rated values for switching capacity (e.g., switching voltage and switching current). If the ratings are exceeded the product may not be able to operate with its rated performance characteristics due to factors such as insulation failure, contact failure, or contact welding. It may even result in damage to or burning of the relay. The lifetime of relays varies significantly with the switching condi- tions. Be sure to confirm the required performance characteristics by testing the relay under actual operating conditions, and use the relay at a frequency at which it can perform with the required perfor- mance characteristics. Continued use of the relay in a state where it cannot maintain the rated characteristics may eventually result in damage to the insulation between circuits or burning of the relay. Do not use the product in locations subject to flammable or explo- sive gases. Doing so may result in fire or explosion due to the arcing that accompanies the switching mechanism and heating up of the relay. No-contact Output (Transistor, Power MOS FET Relay, and SSR Output) Do not use the product for loads that exceed the rated output cur- rent. Doing so may damage output elements and result in short-cir- cuiting or open circuits. When using the product for DC inductive loads, connect a diode that will prevent reverse voltages. Not doing so may damage output ele- ments and result in short-circuiting or open circuits. Correct Use Link Terminals with Relay Outputs This Link Terminal is for relay output. G70D-R6R j1-B7A Link Terminals use 24-VDC G6D-1A Relays and G70D-R6M j1-B7A Link Terminals use 24-VDC G3DZ-2R6PL Relays. When replacing relays, use the yellow Relay Removal Tool at the corner of the screw terminal (except for G7TC). Do not mount or dismount relays with the power supplied. Opening the Front Cover (Rotating Type): Hold the two bottom corners of the front cover (labelled A in the dia- gram below), and lift upwards to open. Replacing Relays Do not mount or dismount relays with the power supplied. Doing so may result in electric shock or malfunction. When replacing relays, use the yellow Relay Removal Tool at the corner of the screw terminal (except for G7TC). Relays must be inserted vertically so that the legs do not bend. Not inserting relays properly may result in malfunction or heating. Wiring Be sure that terminal polarity, wiring between the transmission lines and power supply, and the voltage specifications for I/O power sup- plies are correct. Do not mount or remove connectors with the power supplied. Doing so may result in malfunction. Locks for Connecting Cables Ensure that the connectors for connecting cables are securely locked before supplying power. Installation Do not install the product in the following locations. Doing so may result in failure or malfunction. • Locations subject to direct sunlight • Locations subject to temperatures outside the range 0 to 55°C • Locations subject to humidity outside the range 10% to 90%, or locations subject to condensation as the result of severe changes in temperature • Locations subject to corrosive or flammable gases • Locations subject to dust (especially iron dust) or salts • Locations subject to shock or vibration • Locations subject to exposure to water, oil, or chemicals Tightening Torque for Mounting Screws Tighten the mounting screws for all Units to the specified torques to prevent malfunction. • Tightening torque for terminal screws: 0.78 to 1.18 N ⋅m • When directly mounting to panel with screws: 0.59 to 0.98 N ⋅m Cleaning Do not use thinners to clean the product. Doing so will dissolve or discolor the surface of the product. Mounting Be sure not to drop the product or apply excessive shock to the product when mounting. Doing so will result in failure or malfunction. Disassembly Do not attempt to disassemble, repair, or modify the product. Any attempt to do so may result in incorrect operation or electric shock. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |