110 / 121 page ![]() B7AP B7AP 108 Note: 1. The maximum I/O points refers the maximum I/O points handled simultaneously by the B7A Input and Output Units. Figures in parentheses indicate the maximum I/O points handled simultaneously by the B7A Input and Output Units each connected with an independent power supply. Refer to Power Supplies on page 110. 2. The maximum I/O points are the same as the maximum input points of the B7A Input Unit connected to the B7AP-M1. 3. PLCs and three-wire sensors can be connected only if the B7A Input and Output Units are each connected with an independent power supply. Refer to Power Supplies on page 110. Specifications Communications Specifications Communications method Unidirectional, time-division multiplex Transmission distance (couplers) 8 ±1.5 mm Transmission distance (B7A) 100 m max. (see note 1) I/O delay time Typical: 19.2 ms; 31 ms max. Minimum coupler interfacing time 0.3 s (see note 2) Minimum distance between Power Couplers mounted in parallel 60 mm Note: 1. The value is for the case where a power supply is provided only for the B7AP-S1. 2. Minimum coupler interfacing time is the minimum time required for signal and power transmission between the B7AP-S1 and B7AP-M1 Power Couplers. Characteristics Item B7AP-S1 B7AP-M1 Power supply voltage 24 VDC ±10% --- Current consumption 300 mA --- Insulation resistance 100 M Ω min. (at 500 VDC) between each lead wire and external parts Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between each lead wire and external parts Noise immunity Noise level: 1.5 kV; pulse width: 100 ns to 1 µs (on transmission line due to coupling) Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude Shock resistance 500 m/s2 Ambient temperature Operating: –10 to 55 °C (with no icing or condensation) Storage: –25 to 65 °C (with no icing or condensation) Ambient humidity Operating: 35% to 95% (with no condensation) Cable pulling strength 49 N Nut tightening strength 39 N S m Enclosure rating IEC IP67 Maximum cable length 2 m Weight Approx. 300 g Approx. 230 g EMC Radiated Emissions: EN55022 class A Radiated Immunity: prEN50082-2 Electrostatic Discharge: prEN50082-2 Burst Transients: prEN50082-2 Approved standards UL508 Conforms to EN50081-2, EN50082-2 Moving Unit Specifications Output voltage 12 VDC ±10% Output current 38 mA Note: Use the Moving Unit so that the total current consumption of all input devices is 38 mA max. if power is supplied to the input devices through the Moving Unit. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |