13 / 21 page ![]() www.sensirion.com Version 1 – March 2022 13/21 3.7 Field Calibration To realize high initial and long-term accuracy, the SCD42 includes two field calibration features. Forced recalibration (FRC) enables restoring highest accuracy with the assistance of a CO2 reference value immediately. Typically, FRC is applied to compensate for drifts originating from the sensor assembly process or other extensive stresses. Automatic self-calibration (ASC) ensures highest long-term stability of the SCD42 without the need of manual action steps from the user. The automatic self- calibration algorithm assumes that the sensor is exposed to the atmospheric CO2 concentration of 400 ppm at least once per week. 3.7.1 perform_forced_recalibration Description: To successfully conduct an accurate forced recalibration, the following steps need to be carried out: 1. Operate the SCD42 in the operation mode later used in normal sensor operation for > 3 minutes in an environment with homogenous and constant CO2 concentration. 2. Issue stop_periodic_measurement. Wait 500 ms for the stop command to complete. 3. Subsequently issue the perform_forced_recalibration command and optionally read out the FRC correction (i.e. the magnitude of the correction) after waiting for 400 ms for the command to complete. • A return value of 0xffff indicates that the forced recalibration has failed. Note that the sensor will fail to perform a forced recalibration if it was not operated before sending the command. Please make sure that the sensor is operated at the voltage desired for the application when applying the forced recalibration sequence. Table 18: perform_forced_recalibration I2C sequence description Write (hexadecimal) Input parameter: Target CO2 concentration Response parameter: FRC-correction Max. command duration [ms] length [bytes] signal conversion length [bytes] signal conversion 0x362f 3 word[0] = Target concentration [ppm CO2] 3 FRC correction [ppm CO2] = word[0] – 0x8000 word[0] = 0xffff in case of failed FRC 400 Example: perform forced recalibration, reference CO2 concentration is 480 ppm Write 0x362f 0x01e0 0xb4 (hexadecimal) Command Input: 480 ppm CRC of 0x01e0 Wait 400 ms command execution time Response 0x7fce 0x7b (hexadecimal) Response: - 50 ppm CRC of 0x7fce |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |