5 / 22 page ![]() www.sensirion.com version 1.0 – December 2021 5/22 2 Specifications 2.1 Electrical Specifications Table 2 lists electrical specifications of the SGP41. Default conditions of 25 °C and 3.3 V supply voltage apply to values in the table below, unless otherwise stated. The SGP41 supports both I2C “standard-mode” and “fast-mode” (see NXP I2C-bus specification and user manual). Parameter Symbol Values Unit Comments Min. Typ. Max. Supply voltage, hotplate supply voltage9 VDD, VDDH 1.7 3.3 3.6 V Minimal voltage must be guaranteed also for the maximum supply current specified in this table. VDD and VDDH must be connected to the same power supply, see Figure 6. Idle current IDD – 34 105 A The idle mode is activated after power-up, after calling the sgp4x_turn_heater_off command, or after a soft reset. Supply current during conditioning mode10 – 6.5 7.2 mA Average current consumption while the sensor is continuously operated at VDD, VDDH = 1.8 V. – 4.2 4.6 mA Average current consumption while the sensor is continuously operated at VDD, VDDH = 3.3 V. Supply current during VOC+NOx measurement mode10 – 4.3 4.8 mA Average current consumption while the sensor is continuously operated at VDD, VDDH = 1.8 V. – 3.0 3.4 mA Average current consumption while the sensor is continuously operated at VDD, VDDH = 3.3 V. Communication – Digital 2-wire interface, I2C Table 2 Electrical specifications. 2.2 Timing Specifications Timings in Table 3 refer to the power up and reset of the ASIC part and do not reflect the usefulness of the readings. Parameter Symbol Condition Min. Typ. Max. Unit Power-up time tPU After hard reset, VDD ≥ VPOR – 0.4 0.6 ms Soft reset time tSR After soft reset – 0.4 0.6 ms SCL clock frequency fSCL – – – 400 kHz Table 3 System timing specifications. 9 Any supply voltage as defined by the min./max. range may be used for continuous operation of the sensor. The typical value specifies the supply voltage at which outgoing quality control is performed. 10 Sending the sgp41_execute_conditioning and sgp41_measure_raw_signals command enables continuous operation of the sensor. A 20 % higher current is drawn during 5 ms on VDDH after sending either of the two commands. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |