1 / 3 page ![]() © 2016 Littelfuse Protection Relays & Controls www.littelfuse.com/ Rev: 1-A-062716 Protection Relays Current Monitoring Relays and Transducers www.littelfuse.com/ecsw ECSW SERIES Description The ECSW Series of single-phase, AC window, current sensors includes adjustable overcurrent and undercurrent trip points. Detects locked rotor, jam, loss of load, an open heater or lamp load, a broken belt, or loss of suction. LED’s aid in trip point adjustment and provide fault indication. The built-in toroidal sensor eliminates the need for an external current transformer. The output can be electrically latched after a fault, or automatically reset. Remote resetting of a latched output by removing input voltage. The unit includes switch selectable zero current detection and normally de-energized or energized output operation. Time delays are included to improve operation and eliminate nuisance tripping. Features & Benefits FEATURES BENEFITS Built-in toroidal current sensing Eliminates need to install stand alone current transformer and provides isolation from monitored circuit Encapsulated Protects against shock, vibration, and humidity LED indication Visual indication for trip point adjustment and fault indication Multiple switch selectable features User selectable zero current detection, latched, normally de-energized, or energized output adds application flexibility Adjustable trip delay Eliminates nuisance tripping and prevents rapid cycling Isolated 10A, SPDT output contacts Allows control of loads for AC or DC voltages Operation When the input voltage is applied, sensing delay on startup begins and the output transfers (if normally energized is selected). Upon completion of the startup delay, sensing of the monitored current begins. As long as current is above undercurrent trip point and below the overcurrent trip point (inside the window), the output relay remains in its normal operating condition and both red LED’s are OFF. The green LED glows when the output is energized. If current varies outside the window, the associated red LED glows, and the trip delay begins. If the current remains outside the window for the full Wiring Diagram Current Sensors L1 N/L2 MC = Motor Contactor M = Motor F = Fuses OL = Overload RSW = Reset Switch FSW = Fan or Float Contacts CR = Control Relay CS = Current Sensor MCC = Motor Contactor Coil V = Voltage I> = Adjustable Overcurrent I< = Adjustable Undercurrent W = Monitored Wire ∆T - AdjustableTrip Delay Ordering Information MODEL INPUT VOLTAGE TRIP POINT ADJUST. TRIP DELAY SENSING DELAY ON STARTUP CONNECT. ECSW3LABT 24VDC 0.5 - 5A 0.150 - 7s 0.1s Terminal blocks ECSW4HBHT 120VAC 5 - 50A 0.5 - 50s 6s Terminal blocks ECSW4LADT 120VAC 0.5 - 5A 0.150 - 7s 2s Terminal blocks ECSW4LBHT 120VAC 0.5 - 5A 0.5 - 50s 6s Terminal blocks ECSW4MACT 120VAC 2 - 20A 0.150 - 7s 1s Terminal blocks ECSW4MBHT 120VAC 2 - 20A 0.5 - 50s 6s Terminal blocks ECSW4MBGT 120VAC 2 - 20A 0.5 - 50s 5s Terminal blocks ECSW6MBHT 230VAC 2 - 20A 0.5 - 50s 6s Terminal blocks If you don’t find the part you need, call us for a custom product 800-843-8848 |
类似零件编号 - ECSW3LABT |
|
类似说明 - ECSW3LABT |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |